Remote Control - Casanoov HICKER B200 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69
EN

Remote control

Button "1" depressed to operate single gate;
Button "2" depressed to operate double gate;
Button "3" depressed for alarm output
Program new remote control:
> First step
Press the LEARN button on the control board [29] for about 1 second, the indicator LED would turn off,
then now means have already enter learning Second step:
Press any button of the new remote control for about 2 second, then digital display would show the
remote number while indicator LED on board starts flash four times with one buzzer sound then now
means the learning successfully.
Note! After you press LEARN button, if not receive the new remote signal within 5s, indicator LED would
turn on and exit learning. Remove remote control:
Press and hold the LEARN button for about 5 second, if with one buzzer sound and indicator LED light
on, then now means remove remote successfully.
Setting of the control board
After power on, digital display will self-check from 00-99 with buzzer sound. If indicator LED light on,
buzzer stop sound, it means the system is normal.
Basic operation method:
Press and hold the [ FUN] button until the digital display shows PO. Now you enter the menu setting.
You could through adjust the [INC+] [DEC-] to increase or decrease the serial number or numerical
value. After data adjust well then press [ FUN] to store the data. With one sound of buzzer, the store
successfully.
After store the data, the digital display would still on the menu number you just set, if you need to enter
next menu setting, please press [INC+] or [DEC-] to choose and confirm with [FUN] to enter the menu
number you want to set. Such as after you store the P0 value and press [FUN] to store it, then now the
digital display would still show the number P0, and if you want go further to adjust P1, please press one
[INC+], then digital display show P1, later press [FUN] to enter the P1 setting.
If you not need to enter next menu setting, you could press [LEARN] button to exit the menu setting.
18

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sti-000044

Tabla de contenido