Descargar Imprimir esta página

Glomar EPG-5-PRO Manual De Instrucciones página 6

Publicidad

EPG-5-PRO
EPG-5-PRO
1
2
ERROR CODE:
****
3
BT
P 3
bar
P 3
bar
4a
USER 3:
RD3
Doppelklick
4b
USER SELECT 3:
RD3
Einfachklick
3 sec.
4c
USER SELECT:
RD3
Doppelklick
4d
USER SELECT:
RD3
Doppelklick
Klauke i-press
www.klauke.com/connectivity
Klauke i-press
Authorised Service Center
SWITZERLAND
Glomar AG
Seestrasse 11
CH-9326 Horn
0041 – 71-8417070
0041 – 71-8417018
WARNING
Read all safety warnings, instruc-
tions, illustrations and specifi ca-
tions provided with this power tool.
Failure to follow all instructions listed
below may result in electric shock, fi re
and/or serious injury.
Save all warnings and instructions
for future reference.
HE.18040_B © 02/2017
HE.18040_B © 02/2017
l
Glomar AG
Seestrasse 11
5
6
7
Error code
*1
*2
Bluetooth (if connected)
Battery charging level
Current pressure
Pressure max.
Doubleclick
Singleclick
enter menue
Doubelclick
select
Doubelclick
con rmed
Software
®
App
®
datecode
Year Code Month Code Month Code
2018 M
Jan.
2019
N
Feb.
2020
P
Mar.
2021
Q
Apr.
2022
R
May
2023
S
June
batch# e.g. 304711
datecode e.g. P = 2020; R = April
consecutive# e.g. „142" = tool # 142
WORK
WORK
SERVICE
SERVICE
l
l
CH-9326 Horn
T +41 71 841 70 70
NEXT
SERVICE:
Cycles
9826 OP
(until next service)
s
Since manufacturing:
TOTAL:
operating houres
t = 0
07
h
.
Q = 21
12 Ah
Capacity
.
n = 174
# crimps
optional:
optional:
NG2
NG2
≤ 20 sec.
> 20 sec.
REPEAT
N
July
V
P
Aug.
W
ACHTUNG! Garantiesiegel
Bei Beschädigung Garantieverlust
Q
Sept.
X
ATTENTION! Warranty seal
If broken loss of Warranty
R
Oct.
Y
S
Nov.
Z
T
Dec.
1
304711
PR
142
DON´T DO
DON´T DO
l
www.glomar.ch
*1
Error codes:
1 Overcurrent fuse
2 Overcurrent comparator
3 Overheat board
4 Overheat battery
5 Battery empty, operation stop
6 Faulty crimp
motor in operation
7 Faulty crimp
motor not in operation
8 Low battery
9 Battery empty
10 RTC battery low
11 Tool deactivated
12 Service necessary
13 RTC not found
14 BT unit not found
16 Pressure sensor not found
17 Burst pressure exceeded
18 Battery temperature too low
1 Überstrom durch
Überstromsicherung
2 Überstrom durch Komparator
3 Boardtemperatur zu hoch
4 Akkutemperatur zu hoch
5 Akkuspannung während der
Operation zu gering
6 Fehlpressung bei
laufendem Motor
7 Fehlpressung bei
stehendem Motor
8 Niedrige Akkuspannung
9 Akku leer
10 RTC-Batterie leer
11 Werkzeug deaktiviert
12 Service nötig
13 RTC nicht verfügbar
14 BT-Modul nicht verfügbar
16 Drucksensor nicht verfügbar
17 Berstdruck überschritten
18 Akkutemperatur zu gering
*2
≤ 20 sec.
Auf dem Knapp 46
 D-42855
Remscheid
General
General
safety rules
safety rules
(2Hz)
I
V
6

Publicidad

loading

Productos relacionados para Glomar EPG-5-PRO