Directions For Use; Filter Replacement - Guardian Technologies AC4150 Instruciones De Uso Y Cuidado

Ocultar thumbs Ver también para AC4150:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DIRECTIONS FOR USE

SET UP
1. Select a firm, level and flat location for the air purifier. For proper air flow, locate the unit at
least 1 foot from any wall or furniture. Make sure none of the grills are blocked.
2. Carefully remove your air purifier from box and bag.
3. Adhere 4 felt pads to unit base to protect table top surface. Remove adhesive backing
and apply one pad to each corner of unit base.
4 Felt Pads
OPERATING THE AIR PURIFIER
1. Plug the power cord into a 120V AC outlet.
2. Select 1 of the 3 project lenses. Rotate
lens cap counter clockwise to unlock
position and lift off. Replace with new
lens cap and rotate clockwise to
lock position.
3. Turn unit power ON.
• Select fan speed MODE 1-3
= lowest speed setting
= highest speed setting
4. Select UV-C ON or OFF using UV-C button.
5. Push button on projector lens to control lights.
One push - 3 colors auto-rotate
Continue to push for specific color
E-6
Figure 1
Power & Variable
Speed Control
UV-C Control
UV
Projector Lens Button

FILTER REPLACEMENT

To maintain the performance of the air cleaner, it is recommended that the filter be replaced
about every 6 months. The replacement requirements will vary depending on usage and
environmental conditions.
1. It's time to replace the filter when the white HEPA cartridge portion has changed
from white to grey or black.
OR
2. A filter date wheel is also built into the rear of the unit
to track your filter changes. Simply set the wheel 6 months
ahead from when it is replaced as a reminder. The wheel is
marked with the months of the year (Figure 3).
UV-C BULB REPLACEMENT
1. Lift and remove the
2. After removing the Rear
Rear Cover from the unit.
Cover from the unit, remove
the Combination Filter.
4.The UV-C Bulb is removed by carefully grasping the bulb with
a clean cloth or tissue and pulling the bulb straight out of the
unit (Figure 4).
IMPORTANT: The UV-C Bulb should be replaced every 10-12
months depending on use. Please contact Customer Service at
1.866.603.5900 or visit us at www.guardiantechnologies.com to
purchase a replacement bulb.
Replacement UV-C Bulb: LB4100.
Pull UV-C Bulb
straight out of unit.
Figure 4
3. After removing the
Combination Filter, use a
Philips head screwdriver
to remove screw and detach
the UV-C Shield.
5.The UV-C Bulb is reinstalled by sliding it,
horizontally, back into the slots.
Figure 3
E-7