Instalación
Conexiones eléctricas
ADVERTENCIA!
Read the Electrical requirements and grounding
instructions before connecting the tumble dryer.
Electric models of the dryer are manufactured for
a 3-wire connection system. The dryer frame is
grounded by a link to the neutral conductor on the
dryer terminal block. If local codes do not permit
grounding through the neutral, the grounding link
from the terminal block must be removed and a
separate ground wire must be used.
Only a 4-conductor cord shall be used when the
applience is installed in a location where
grounding through the neutral conductor i
prohibited. Grounding through the neutral
conductor is prohibited for new branch-circuit
installations, mobile homes, recreational vehicles,
and areas where local codes prohibit grounding
through the neutral condutors. The grounding link
on the dryer must be removed for all 4-wire
installations.
These Electrical Connection instructions provide
for installing the dryer in the following situations:
3-wire connection where local codes permit
grounding through the neutral. 3-wire connection
plus separate grounding connector where local
codes do not permit grounding through the
neutral.
4-wire connection.
Each of the above connections can be made with
an approved power supply cord or by direct wiring.
Each connection instruction identifies the
appropriate Power Supply Cord and covers
requirements for direct wiring.
NOTA!
En Canadá, la secadora se suministra lista, con
una clavija de cuatro patas prevista para la
conexión a un suministro monofásico.
All manuals and user guides at all-guides.com
Customer Care Center
1-800-898-1879
www.askousa.com
Conexión de un cordón de energía de tres
cables
ADVERTENCIA!
Antes de comenzar este procedimiento, verifique
que la energía eléctrica esté apagada en la caja
de fusibles o en el cortacorriente.
Cable eléctrico
Necesitará un cable tripolar, con tres hilos de
cobre nº 10 y un receptáculo tripolar de tipo
NEMA 10-30R, como se ilustra:
Para conectar un cable tripolar a la secadora, siga
los pasos a continuación.
NOTA!
Los números de la ilustración se corresponden
con los números de los pasos.
1. Apague la energía en la caja de fusibles o en
el cortacircuito.
2. Quite la cubierta del bloque terminal.
3. Ensamble un protector contra tirones de ¾
pulg aprobado por UL dentro del orificio debajo
de la abertura del bloque terminal.
4. Afloje o quite el tornillo central del bloque
terminal.
27