Descargar Imprimir esta página

Stanley FATMAX FMHT1-77415 Manual Del Usuario página 9

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
3.
Aim the laser's vertical line at the first corner or reference
point (Figure
#1).
F
4.
Measure half the distance across the wall (D
(Figure
#1).
F
5.
Where the horizontal laser line crosses the halfway point
(D
), mark point P1 (Figure
1/2
6.
Rotate the laser to another corner or reference point
(Figure
#2).
F
7.
Where the horizontal laser line crosses the halfway point
(D
), mark point P2 (Figure
1/2
8.
Measure the vertical distance between P1 and P2
(Figure
#3).
F
9.
If your measurement is greater than the Allowable
Distance Between P1 & P2 for the corresponding
Distance (D1) in the following table, the laser must be
serviced at an authorized service center.
Distance (D1)
Between P1 and P2
9 m (30')
12 m (40')
15 m (50')
Horizontal Line Accuracy - Level
Checking the level of the laser's horizontal line requires a flat
vertical surface at least 30' (9 m) wide.
1.
Place the laser at one end of the wall as shown
in Figure
#1, and turn the laser ON.
E
2.
Press
once to display a horizontal line.
3.
Mark two points (P1 and P2) at least 30' (9 m) apart along
the length of the laser's horizontal line on the wall
(Figure
#1).
E
4.
Relocate the laser at the other end of the wall and align the
laser's horizontal line with point P2 (Figure
5.
Mark point P3 on the laser line near point P1
(Figure
#2).
E
6.
Measure the vertical distance between points P1 and P3
(Figure
#2).
E
)
1/2
#1).
F
#2).
F
Allowable Distance
3 mm (1/8")
4 mm (5/32")
5 mm (7/32")
#2).
E
7.
If your measurement is greater than the Allowable
Distance Between P1 & P3 for the corresponding
Distance Between P1 & P2 in the following table, the laser
must be serviced at an authorized service center.
Distance Between
P1 & P2
9 m (30')
12 m (40')
15 m (50')
Vertical Line Accuracy - Plumb
Checking the plumb of the laser's vertical line.
1.
Measure the height of a door jamb (or a reference point on
the ceiling) to get height D1 (Figure
2.
Place the laser as shown in Figure
ON.
3.
Press
twice to display a vertical line.
4.
Aim the laser's vertical line toward the door jamb or the
reference point on the ceiling (Figure
5.
Mark points P1, P2, and P3, as shown in Figure
6.
Move the laser to the opposite side of point P3 and aim the
laser's vertical line toward point P2 (Figure
7.
Align the vertical line with points P2 and P3, and mark point
P4 (Figure
#2).
G
8.
Measure the distance between P1 and P4 (Figure
9.
If your measurement is greater than the Allowable
Distance Between P1 & P4 for the corresponding Vertical
Distance (D1) in the following table, the laser must be
serviced at an authorized service center.
Height of Vertical
Distance (D1)
2.5 m (8')
5 m (16')
6 m (20')
9 m (30')
Allowable Distance
Between P1 and P3
6 mm (1/4")
8 mm (5/16")
10 mm (13/32")
#1).
G
#1 and turn the laser
G
#1).
G
#1.
G
#2).
G
#3).
G
Allowable Distance
Between P1 and P4
1.5 mm (1/16")
3.0 mm (1/8")
3.6 mm (9/64")
5.5 mm (9/32")
GB
9

Publicidad

loading

Este manual también es adecuado para:

Fatmax fmht1-77442