HOW TO SET THE PRESENT TIME

1. Press the button ST three times.
The time indication alone flashes.
2. Press the H button until the present time hour is
displayed. Press the M button until the present time
minutes are displayed. The display will automatically
stop flashing.
COOLING
NOTE
EG
Verify that the unit is connected to the
main power and the STANDBY lamp is
light up.
1.Set the
selector to COOL (symbol
on the display).
2.Press the +/- buttons (temperature
selection) to set the desired temperature
(the temperature range is between 32 °C
max. and 10 °C min.).
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
3.Press the FAN button to select the fan speed.

HEATING

1.Set the
selector to HEAT (fixed or blinking symbol
on the display.
2.Press the +/- buttons (temperature selection) to set the desired
temperature (the temperature range is between 32 °C max.
and 10 °C min.).
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
3.Press the FAN button to select the fan speed.
NOTES
For several minutes after the start of heating operation, the
indoor fan will stop until the indoor heat exchanger coil has
warmed up sufficiently. This is because the COLD DRAFT
PREVENTION SYSTEM is operating. During this period, the
STANDBY lamp remains lit.
Generally the fan stops when the set temperature is exceeded
(when you have selected the fixed HEATING symbol
HEATING RECIRCULATION FUNCTION
If you want to let the fan run even after the set temperature
is exceeded, for example, in order to make the heating, coming
from a nearby source, circulate (eg. fireplace installed under
the air conditioner), press the selector
HEATING symbol
is displayed.
8-06-2018
12:28
C
1
1
2
2
3
AFTER 5 SECONDS FROM THE
REQUIRED TEMPERATURE SETTING
THE DISPLAY WILL SHOW THE ROOM
TEMPERATURE AGAIN.
AFTER 5 SECONDS FROM THE
REQUIRED TEMPERATURE SETTING
THE DISPLAY WILL SHOW THE ROOM
TEMPERATURE AGAIN.
until the blinking
Pagina 6
DEFROSTING OF OUTDOOR UNIT HEAT
EXCHANGER
When the outdoor temperature is low, frost or ice may
appear on the heat exchanger coil, reducing the heating
performance. When this happens, a protection function for
the heat exchanger defrosting is activated. During this
function operation, the fan of the indoor unit stops. Heating
operation restarts after several minutes. (This interval will
vary slightly depending on the room and outdoor
temperature).
HEATING PERFORMANCE
A heat pump conditioner heats a room by taking heat from
outside air. The heating efficiency will fall off when the
outdoor temperature is very low. If enough heat is not
obtained with this air conditioner, use another heating
appliance in conjunction with it.

AUTOMATIC OPERATION

1.Set the
or
selector to AUTO (symbol
the display; also the symbol
2.Press the +/- buttons (temperature selection) to set the
desired temperature (the temperature range is between
32 °C max. and 10 °C min.).
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
3.Press the FAN selector button to the setting you want.
During Automatic Operation the unit adjusts the room
temperature understood as "perceived".
The perceived temperature depends on the value of the room
relative humidity, according to the "humidex" index.
When this setting is selected, the air conditioner will operate
automatically switching to the COOL or HEAT mode as
appropriate (regardless of the symbol displayed).
Example of operation diagram in the
the set room temperature at 23°C.
27
A
26
25
B
24
C
23
C
22
21
B
20
A
19
Δ
1
ON
MIN.
NOTE
The air conditioner changes the operation mode (from cool
to heat or vice versa, if one of the following conditions
).
occurs:
- ZONE A: changes if the difference between the room
temperature and the temperature set on the remote control
unit is at least 3°C..
- ZONE B: changes if the difference between the room
temperature and the temperature set on the remote control
unit is at least 1°C, one hour after the compressor stop.
- ZONE C: never changes if the difference between the
room temperature and the temperature set on the remote
control unit is no more than 1°C.
6
on
or
remains displayed).
AFTER 5 SECONDS FROM THE
REQUIRED TEMPERATURE SETTING
THE DISPLAY WILL SHOW THE ROOM
TEMPERATURE AGAIN.
(Auto) mode with
Δ
H
1
H
ON
ON
MAX.