"Ubinas" - ref. 634 10 47/634 10 48
Very important ! The power supply cable is resistant to
temperatures of 300°C. Ensure that the same type of
cable is used if it is replaced.
2.12. Hot air outlets
Figure 13
In the case of the insert fire being the hearth of a
chimney to be built, it is possible to fit two outlets to
diffuse air to adjacent rooms. In this respect :
-
Remove the blanking plates on the casing on top of the
appliance.
-
Secure the 5 mm O.D. screws.
-
Fit the flue collars supplied by rotating them.
-
Use insulated flexible pipe dia. 125 mm.
-
Avoid using pipes longer than 6 meters.
-
Eventually use hot-air vent controls.
2.13. Pre-utilisation check
-
Check that the seals of the smoke-line are in good
condition. Check that the door closes correctly. Check
that the glass is not damaged. Check that the smoke
passages are not obstructed by packaging or
removable parts. Check that all removable parts are
correctly installed.
Note : If it acts of a ceramics braid, it is consumable and
thus brought to be changed by the user.
2.14. Flue baffle
The baffle plate is laid in the hearth when it leaves the
factory. Install flue baffle (attached on hearth grate
before leaving the plant) inside combustion chamber.
Technical manual "646"
1
2.15. Flue baffle mounting
Flue baffle mounting : Figure 14
A
3
- Flue
- Hearth
1
2
baffle
decoration plate
Figure 14 - Flue baffle mounting
-
First slide section A over front dampers 3 then lay
section B on hearth decoration plate 2.
To rest part A on blocks 3.
Removing the flue baffle : Figure 15
A
3
1
- Flue baffle
2
- Hearth plate
Figure 15 - Removing the flue baffle
Raise the front of the deflector A, slide it above the
stops 3 before removing the back B resting on the
decorative back hearth 2. Director the deflector into the
stove as indicated in figure 15.
Installation instructions
2
Figure 13 -
Hot air
outlets
B
1
2
- Blocks
3
1
B
2
3
- Blocks
10