6.
Mount the switch in the rack using standard screws (not provided).
Caution
Air vents must not be blocked and must have free access to the room
ambient air for cooling. ! 13
7.
Apply AC power to the switch by plugging the power cord into the AC
power connector on the back panel of the unit (shown in Figure 1) and
plugging the other end into a power outlet.
As power is applied to the switch, the Fault LED (shown in Figure 2)
flashes as the switch runs a series of internal self tests. Refer to the
sections "Switch LEDs" on page 9 for information on the system LEDs.
Warning
The power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord. ! 10
8.
Connect the data cables, making sure each connection has a good valid link
and that the switch is receiving packets. For 10/100Base-TX ports, use a
straight-through cable to connect to workstations and servers, or use a
crossover cable to connect to hubs, routers, or other switches.
9.
Go to the procedure "Setting Up for Local Management" on page 8 to access
the Omega management interface on the switch.
AT-8216FXL, AT-8224XL, and AT-8288XL Series Quick Install Guide
7