1.4 INRUSH CURRENT
150A max. when ac input 230Vac and 250C cold start.
1.5 POWER EFFICIENCY
Meet 80 Plus Gold requirement
1.6 LEAKAGE CURRENT
3.5mA max.
1.7 POWER FACTOR
PF > 0.96 at 230Vac input and full load
1.8 ErP REQUIREMENT
Meet ASM and ErP Lot 3 2014
2.0 OUTPUT:
DA550-G
Voltage
Max load
*
Min load
Peak load
Combined power
*
Regulation
*
Ripple & Noise
*
*
The continuous total output power is 550W max.
• The combined power of +5V and +3.3V is 100W max.
• Peak currents may last up to 12 seconds with not more than one occurrence
per minute.
*
Add 0.1uF and 10uF capacitors across output terminal during ripple & noise test.
*
LOAD REGULATION TEST TABLE:
02
+5V
+3.3V
20.0A
20.0A
0.0A
0.0A
--
--
100W
+3,-3%
+3,-3%
30mV
30mV
+12V
-12V
45.5A
0.3A
0.0A
0.0A
--
--
--
--
+3,-3%
+10,-10%
40mV
40mV
+5Vsb
2.5A
0.0A
3.0A
--
+3,-3%
30mV