+5V
10000uF
2.7 RISE TIME
20ms max at full load.
3.0 PROTECTION:
When OVP ,OPP ,OCP,OTP or short protection is triggered, the main outputs
will be latched off. The main outputs can be reset by cycling the DC remote on/off
or AC power. +5Vsb output is auto recovery when fault condition removed.
3.1 OVER VOLTAGE PROTECTION
+3.3V output
+5.0V output
+12.0V output 15.6 Vmax.
3.2 SHORT circuit PROTECTION
All output to GND.
3.3 OVER POWER PROTECTION
Foldback at 110%~150% over peak load
3.4 OVER CURRENT PROTECTION
DA550-G/ DA650-G
+3.3V output: 22A-32A.
+5.0V output: 22A-32A.
+12.0V output: 50.05A-68.25A.
DA750-G
+3.3V output: 22A-32A.
+5.0V output: 22A-32A.
+12.0V output: 68.2A-93A.
DA850-G
+3.3V output: 22A-32A.
+5.0V output: 22A-32A.
+12.0V output: 77.55A-105.75A.
3.5 OVER TEMPERATURE PROTECTION
Protection temperature is 45℃ to 55℃ at 115V and full load
+3.3V
+12V
10000uF
10000uF
4.5 Vmax.
7.0 Vmax.
-12V
+5Vsb
470uF
3300uF
07