VA-4030(e) and 2060(e) Product Description The VA-2060 is a digital networked two-channel amplifier. It is CobraNet enabled and capable of delivering continuous audio power at 60 Watts RMS per channel. The VA-2060 also has comprehensive failover capability with device-to-device and channel-to-channel failover. The VA-2060e is a digital networked two-channel amplifier.
VA-4030(e) and 2060(e) Setup and Installation Setup and Use The Vocia software provides an intuitive interface for configuration of the VA-4030(e) and VA-2060(e) Amplifiers. The information supplied by this manual relates to physical connections and assignment. For more details on software setup, please consult the Vocia Help File. Installation The unit requires one 3.5 inch (88.9mm) high and 19 inch (483mm) wide rack space with 17.5 inch (444mm) depth.
VA-4030(e) and 2060(e) Front System Indicators The LED indicators on the front panel of the amplifier provide information and operational status of the amplifier and its associated output channels. LED layout and features vary between amplifier models. LED’s are grouped to show chassis status indication and amplifier channel status indication. Amplifier Chassis Indicators These indicators relate to the entire amplifier unit (chassis).
Página 5
Amp Channel Indicators These indicators relate to each amplifier channel. Amp Fault The Amp Fault illuminates when a channel fault has occurred. • Amber - the amplifier channel has a fault and audio may have stopped. • Flashing Amber - the amplifier channel is not performing within normal specification. Activity The Activity LED will illuminate when the channel is configured.
Página 6
VA-4030(e) and 2060(e) Rear Conventions All numbered audio, relay and power connectors on the rear panel of the amplifier are configured with the lowest output or input on the right of the connector as viewed from the rear of the unit. AC Power Socket Provides for connection of the appropriate power cord.
Auxiliary Power The VA-2060e and VA-4030e support 48V DC Auxiliary power connections. The VA-2060 and VA-4030 do not support 48V DC Auxiliary power connections. This connection allows dual DC power inputs to be used. Dual DC supply capability allows the amplifier to meet standards that call for redundant power supplies.
Página 13
Left LED Right LED Description None None No Data Connectivity or CobraNet activity None Green Link established Flashing yellow Green Link established and CobraNet activity detected; The unit is acting as a CobraNet Performer Flashing yellow Flashing green Link established and CobraNet activity detected; The unit is acting as a CobraNet Conductor Flashing yellow None CobraNet fault.
Página 14
• C – Relay Common • NC – Normally Closed • NO – Normally Open CAUTION All Speaker wiring connections should be made by qualified personnel and with the amplifier power removed. The 100V output requires Class 3 wiring. Please refer to a qualified electrician or other qualified person according to local codes. Amplifier Output Connections Transformer Load Selection The required amplifier output load is configured via the use of a recessed indented selector above the...
Página 15
VA-4030(e) and 2060(e) Fault Detection Output Fault Detection The Amplifier monitors (supervises) for faults on speaker connections using a combination multiple out-of- band (inaudible) high frequency tones for end-of-line detection, and DC current for ground fault detection. For end-of-line detection, one or more (up to 15 maximum) ELD-1 units must be connected to the end/s of the speaker line.
Página 16
Failover is triggered by any of the following conditions: • Chassis Fault • Channel Fault • Loss of power • Loss of CobraNet link • Loss of Failover Link Cable • ELD-1 / speaker line Fault (if enabled in software) •...
Página 17
1:1 or 3:1 channel failover is triggered by one of the following conditions: • Heatsink fault (over temperature) • Short circuit fault • Channel failure fault • ELD-1/speaker line fault if enabled in software The redundant channel may be wired in parallel to the existing speaker line or connected to a redundant speaker line.
Página 18
VA-4030(e) and VA-2060(e) Current Draw and Heat Output To determine the Watts and heat output for the configuration, start by finding the total power for the configured Vocia chassis. Then refer to the column that describes the type of audio levels the amplifier will be producing.
To reduce the risk of fire, use only No. 26 AWG solid copper wire for telecom circuit connections. Intended for Installation and Service by Skilled Personnel Only: CAUTION – To reduce the Risk of Electric Shock, Installation and Service of Biamp Products should be conducted only by Skilled Persons who are Biamp Qualified Audio Installation Professionals.
Para la instalación y mantenimiento solo por parte de personal calificado: PRECAUCIÓN – Para reducir el riesgo de descarga eléctrica, la instalación y el mantenimiento de los productos Biamp deben ser realizados por personas calificados que formen parte de los Profesionales capacitados en la instalación de audio de Biamp.
Installation et interventions réservées au personnel compétent: MISE EN GARDE – Pour limiter les risques d’électrocution, l’installation des produits Biamp et les interventions sur ces produits doivent être réalisées uniquement par du personnel compétent faisant partie des professionnels d’installation audio qualifiés de Biamp.
Brandrisiko zu reduzieren. Ausschließlich für Einbau und Wartung durch geschultes Personal vorgesehen: VORSICHT – Zur Verringerung der Stromschlaggefahr sind Einbau und Wartung von Biamp-Geräten ausschließlich durch geschulte Personen, bei denen es sich um von Biamp geschulte Audio-Fachleute handelt, vorzunehmen. Führen Sie keine anderen als die in der Betriebsanleitung angegebenen Wartungsarbeiten aus, vorausgesetzt, Sie wurden hierfür geschult.
Página 28
위험을 줄이기 위해서는 전기 통신 회로 연결은 26번 AWG 솔리드 동선만 이용하십시오. 공인 전문가의 설치 및 서비스: 주의 – 전기 충격의 위험을 줄이기 위해, Biamp 제품의 설치 및 서비스는 Biamp 공인 오디오 설치 전문가에게 의뢰해야 합니다. 전문 인력이 아닌 경우, 작업 지침에 담긴 내용 이외의 사항에 대해 서비스를 제공하면 안됩니다.
Página 29
.لتمديدات روابط دائرة االتصاالت AWG 26 :هذا الجهاز معد للتركيب والصيانة من قبل الموظفين الماهرين فقط Biamp إال من قبل األشخاص المهرة وهم المهنيون المؤهلون تنبيه - للحد من خطر حدوث صدمة كهربائية، ينبغي أال يتم تركيب وصيانة منتجات .Biamp في...
Destinado para Instalação e Manutenção apenas por Pessoal Qualificado: ATENÇÃO – Para reduzir o risco de choque elétrico, a instalação e a manutenção dos produtos Biamp devem ser realizadas somente por pessoas qualificadas, que são profissionais de instalação de áudio qualificados da Biamp.
одножильный медный провод типа 26 AWG. Предназначено для установки и обслуживания только опытным персоналом ПРЕДОСТЕРЕЖЕНИЕ! Для снижения риска поражения электрическим током установку и обслуживание устройств Biamp должны выполнять только лица, которые являются опытными специалистами по установке аудиосистем Biamp. Не проводите какое-либо обслуживание, помимо указанного в инструкциях по эксплуатации, если вы не обладаете соответствующим опытом и...
CAUTION – changes or modifications not approved by Biamp could void the user’s authority to operate the equipment...
Página 33
RoHS COMPLIANT This Biamp product, including all attendant cables and accessories supplied by Biamp, meets all requirements of EU Directives 2011/65/EU of 8 June 2011, the EU RoHS Recast. An EU RoHS Materials Content Declaration document may be obtained at www.biamp.com (This information is presented to comply with the requirements of Chinese law SJ/T11363-2006) 有害物质表...
Página 34
The Warranty Period for the products described in this manual shall be five (5) years. The Warranty Period begins (a) the date of the original end user’s purchase from an authorized Biamp Systems dealer or (b) six months after the product is first shipped from Biamp Systems’...