Door switch
The door switch refers to the switch on the sauna door. This switch com-
plies with regulations. Public and private saunas must have a door switch,
i.e. saunas where the heater can be switched on from outside the sauna,
e.g. using an On/Off button or a similar method.
For additional information about door switch. www.tylohelo.com
Remote controlling
The Heater can be remotely controlled by connecting a closed contactor,
which can be pulse triggered, to connectors 3 and 4 of a RJ10 circuit board.
The recommended cable size is AWG 24 or 26.
The maximum length of an AWG 24 cable is 200 m.
The maximum length of an AWG 26 cable is 130 m.
Principle coupling when Pure is used
as control panel
Heater
Sensor cable
1 = Blue
OLEA 103
2 = White
3 = Red
4 = Yellow
Heater
Apter circuit board
OLEA 103
Sauna heater's
Power
connection cable
H07RN –F/ 60245
IEC 66
mm²
kW
400V 3N~
6,8
5 x 1,5
10,5
5 x 2,5
Table. Connection cable and fuses
Connection of the sauna heater to the mains
The sauna heater must be connected to the mains by a qualified electrician and in compliance with current regulations. The
sauna heater is connected with a semi-permanent connection. Use H07RN-F (60245 IEC 66) cables or a corresponding type.
Other output cables (signal lamp, electric heating toggle) must also adhere to these recommendations. Do not use PVC
insulated cable as a connection cable for the sauna heater.
Helo Water Tech (Helo-WT) in a Himalaya heater
Helo-WT uses the heater's thermal energy to heat water and raise the moisture level without a separate heat source.
Moisturised air improves the sauna climate, and various fragrances and salts can be evaporated to make the sauna experience
more enjoyable.
For additional information about Helo-WT :
Terminal block
4
3
2
1
Sensor OLET 31
A1 Yellow
A2 Green
A3 Red
A4 Black
Sauna heater's
Fuse
connection cable
H07RN –F/ 60245
A
230V 3~
3 x 10
3 x 16
www.tylohelo.com
Limiter
Control panel
pure
Fuse
IEC 66
mm²
A
4 x 4
3 x 20
4 x 6
3 x 35
Door switch
Min. 300 mm
Magnet on
the door
Door switch
position when
installed on
lower part of the
door
Sauna heater's
Fuse
connection cable
H07RN –F/ 60245
IEC 66
mm²
A
230V 1 N~ / 2~
3 x 6
1 x 35
----------
--------
3
Junction box
Max 18 mm