Electrical connection / Surface Mount
For Synchronization:
Connect YELLOW wires of all heads to-
gether for synchronization (all heads must
be set at the same pattem)
For Simultaneous or Alternating Flash:
1. Apply +VDC to RED and YELLOW wires
simultaneously to enter Grouping mode;
lighthead will display short (single or
double) flashes:
23
• Single flash = Group 1
• Double flash = Group 2
2. Remove YELLOW wire from +VDC and
momentarily apply to +VDC to change
Groups:
• Heads in the same Group flashtogether.
• Group1 Heads alternate with Group2
Heads.
For Flash Patterns:
Momentarily apply +VDC to
YELLOW wire:
• once for next pattern
• quickly three times for pattern 0
3/6 x LED / R65
FP-Nr.
flash sequence:
0
Triple *
1
Single *
2
Double *
3
Triple *
4
Quadruple *
5
Steady
3 x LED / SAE
FP-Nr.
flash sequence:
0
Double
1
Single
2
Double
3
Triple
4
Quadruple
5
Quint
6
Mega
7
Giga
8
Ultra
9
Steady
* Only the flash patterns 1, 2, 3,
and 4 are approved for use in
Europe.
6 x LED / SAE
FP-Nr.
flash sequence:
0
Double
1
Single
2
Double
3
Triple
4
Quadruple
5
Quint
6
Mega
7
Giga
8
Ultra
9
Steady
10
Single (split)
11
Double (split)
12
Triple (split)
13
Quadruple (split)
14
Quint (split)
15
Mega (split)
16
Giga (split)
17
Ultra (split)
red / blue
FP-Nr.
flash sequence:
0
Triple (split)
1
Triple (red only) [R 65]
2
Triple (blue only) [R 65]
3
Single (split)
4
Double (split)
5
Triple (split)
6
Quadruple (split)
7
Steady (red only)
8
Steady (blue only)