Trotec TDS 20 Manual Operativo página 5

Ocultar thumbs Ver también para TDS 20:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
REGULATING THE THERMOSTAT
By rotating the knob that controls
the thermostat, you can regulate
the room temperature.
When the desired temperature is
reached the thermostat automati-
cally switches the resistance off but the fan continues
working.
MANUAL RESETTING
The appliance comes with a built in security device
that goes off automatically if the appliance should
happen to overheat.
If the security device should go off, let the appliance
cool down before looking for the cause of the problem.
Should the problem persist, contact the Service Centre.
PERIODIC STORAGE AND CONTROL
If the appliance is not used for a long period of time, it
should be cleaned before being put away. Store it in a
dry place and protect it from dust. When the appliance
is used again check to make sure that the electric
cable is not damaged. Should you have any doubts as
to the conditions of the appliance please contact the
Service Center.
The appliance should be checked at least once a year.
Only qualified personnel authorized by the manufac-
turer must carry out all repairs.
SINGLING OUT PROBLEMS
Problem:
The appliance works but does not
heat
The appliance does not switch on
Limited air flow
EN
TECHNICAL DATA
Capacity . . . . . . . . . . . . . . . . . . . . . . . . 1,65 -3,3 kW
Absorbed current . . . . . . . . . . . . . . . . . . . . . 14,35 A
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . .230 V/50 Hz
Air displacement . . . . . . . . . . . . . . . . . . . . .333,2 m
Thermostat range . . . . . . . . . . . . . . . . . . . . . 0-40 °C
Size (mm) . . . . . . . . . . . . . . . . . . . . .410 x 260 x 250
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5,6 kg
Cause:
Resistance is burnt out
Thermostat control is broken
Faulty motor
Power supply interrupted
Air duct obstructed
Faulty motor
Operating Manual – Electric hot air generator
Solution:
Replace
Replace
Replace
Unplug the appliance and check
connection.
Clear the passage
Replace
/h
3
B - 2

Publicidad

Tabla de contenido
loading

Tabla de contenido