Sensor Installation; Controller Installation; Connecting The Components - Proven Pumps PVL-PRO-33V Manual Del Usuario

Tabla de contenido

Publicidad

SENSOR INSTALLATION

IMPORTANT: The sensors will turn the pump ON
and OFF once the water reaches the metal tip on the
bottom of the sensor. Keep this in mind when you
are positioning the sensors onto the discharge pipe.
1. Using the zip tie strap connect the red ON sensor
to the discharge pipe at the height where you
want the pump to turn ON. NOTE: The bottom
of the sensors should be below the drain tile and
away from the incoming water to avoid false
triggering of the system as shown in the figure
below.
2. Using the zip tie strap connect the black OFF sen-
sor to the discharge pipe at the height where
you want the pump to turn OFF.
DRAIN TILE
RED SENSOR
ON POINT
BLACK SENSOR
OFF POINT
NOTE: Basins with high mineral content or water
softener discharger may require additional bracket
kit for sensors (Part# STBRKT3)
NOTE: Do not completely tighten zip tie strap until
you have an exact position and mark the pipe for fu-
ture reference. When replacing use 10" zip ties.

CONTROLLER INSTALLATION

1. Pull the battery cables through the large circle
opening on the face of the battery box
2. Align the predrilled holes on the controller to the
holes on the battery box.
3. Push the bolts through the controller holes into
the battery box holes and tighten wing nuts.
4. Make sure the controller is securely fastened to
the battery box
CONNECTING THE BATTERY:
1. Follow all safety instructions and precautions in
both this manual and per the battery manufac-
ture.
2. Place the battery into the battery box with the
posts facing the front of the box.
3. Connect the black negative (-) ring terminal to
the negative (-) post on the battery.
4. Connect the red positive (+) ring terminal to the
positive (+) post on the battery.
5. Fasten securely using an insulated wrench
6. The system should now come on

CONNECTING THE COMPONENTS:

PUMP: Connect the pump cables by sliding the larg-
er positive (+) terminal onto the larger positive (+)
pump receptacle on controller. Slide the smaller
negative (-) terminal onto the smaller negative (-)
pump receptacle on the controller.
SENSORS: Connect the RED sensor into the Top Sen-
sor (ON) receptacle and the BLACK sensor into the
Bottom Sensor (OFF) receptacle on the left side of
controller.
CHARGER: Connect the charger unit into the AC
Power receptacle on the left side of the controller
and then into the wall.
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bsc33v

Tabla de contenido