Motion Sensor Quartz
Security Light
Model SL-5309
The Motion Sensor Quartz Security Light turns on 300
watts of quartz-halogen lighting when motion is de-
tected and then, after a selectable period of time,
automatically turns the lighting off. The built-in photocell
keeps the lighting off during daylight hours.
This package includes:
Sensor
Light Control
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch – not a dimmer or other
electronic switch.
• Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
• The backplate has knockouts so the sensor can be
mounted on most junction boxes.
• In some applications a universal adaptor plate may be
needed. Adaptors are available at Home Centers and
Electrical Supply Stores.
OPERATION
Mode:
On-Time:
Test
5 Sec
Auto
1, 5, 10 min.
Manual
Until Dawn*
* resets to Auto Mode at dawn.
© 2003 DESA Specialty Products™
Cover Plate
Gasket
Cover
4 Screws
Plate
(2 sizes)
Halogen
Bulb
3 Wire
Connectors
Long Bolt
Works:
Day
Night
x
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5 or
10 minute position.
Manual mode only works at night be-
cause daylight returns the sensor to
AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ON-
TIME switch in the 1, 5, or 10 position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time (1
AUTO mode.
INSTALLATION
For easy installation, select an existing light with a wall
switch for replacement.
x
x
x
TEST
AUTO
ON-TIME
10 5 1 TEST
MANUAL MODE
1 Second OFF
... back on.
Move ON-TIME Switch
to 1, 5 or 10 minutes
Flip switch off for
one second then
back on*
1
/
min.) the control will be in the
2
❒ Attach the lamp arm to
the backplate arm and
secure with the long bolt.
Note: When tightening the
arm screw, pull on the wires
to make sure the wires are
not pinched by the joint.
ON-TIME
10 5 1 TEST
then...
595-5496-06