9. TROUBLESHOOTING

PROBLEM
LEDs do not light,
or converter does
not function.
Green LED is
flashing.

10. SPECIFICATIONS

Maximum output ........................................... 100W intermittent, 85W continuous
Surge capacity (0.1 Second) .......................................................................200W
Full load input current ...................................................................................<10A
Optimum efficiency ........................................................................................ 85%
No load current draw ...................................................................................<0.5A
AC output frequency ............................................................................ 60Hz±3Hz
AC output wave form ..............................................................Modified sine wave
AC output voltage range ................................................................. 120V AC±5%
DC input range .....................................................................10.5V DC-15.5 V DC
Low voltage shutdown .........................................................<10.5V DC±0.3V DC
High voltage shutdown ...................................................................... 15.5V±0.3V
USB port current ......................................................... Max. combined current 2A
Overload protection ........................................................................................ Yes
Dimensions (main module L x W x H)........................................7" x 3.25" x 1.75"
Dimensions (satellite module L x W x H) .......................................3" x 2.5" x 1.5"
Weight ......................................................................................................0.75 lbs.

11. REPLACEMENT PARTS

Replacement fuses can be purchased at most electronic component retailers.
POSSIBLE CAUSE
Poor contact at terminals.
Blown fuse.
Converter has shut down.
The continuous load demand
of the device being operated
exceeds the continuous load
rating of the converter.
Unplug and reinsert the 12V plug.
Replace the fuse.
See LED Indicator and Shutdown
Protection section.
Use a higher capacity converter
or a lower rated device.
8