below the power line at a 90° angle and as close as possible.
Do not power an electric animal fence with two separate electric fence energisers or from the
►
independent fence circuits of the same energiser.
Barbed wire or razor wire must not be electrified with an energiser.
►
Non-electrified barbed wire or razor wire may be used to support one or more offset electrified
►
wires of an electric animal fence. The electrified wires must be kept at a vertical distance of at
least 150 mm from the non-electrified wires by means of supports. Make sure that the non-
electrified wire is earthed at regular intervals.
There must be a minimum distance of 2.5 m between two separate electric animal fences, which
►
are powered by separate independently clocked electric fence energisers. If there should be a
physical barrier between the fences then only use electrically non-conductive materials or an
insulated metal barrier.
Ensure that all mains-operated auxiliary equipment connected to the electric animal fence has
►
the same degree of insulation as the energiser used.
Ensure that the auxiliary equipment is weatherproof. Outdoor use is only permitted if it has been
►
certified by the manufacturer and the equipment has a minimum degree of protection of IPX4.
2.3 SAFETY DURING OPERATION
WARNING AGAINST ELECTRICAL VOLTAGES
Lightning can cause fires and lead to malfunctions on electric fences. Separating the energiser
►
from the fence and power source before a storm or possible lightning strike can minimise the
effects of lightning. Redirect the current of the lightning strike to the ground before it damages
the energiser by installing a lightning rod between the fence and the energiser.
Avoid placing combustible objects near your electric fence. Cutting back shrubs in the vicinity
►
also reduces the risk of fire, as short circuits in the fence system can cause sparks.
Do not use an energiser if there is a risk of flooding the electric animal fence.
►
If the interval between pulses is less than 1 second, the energiser must be switched off
►
immediately and repaired, if necessary. If the pulse interval is more than 1.7 seconds, the fence
is no longer secure and the energiser must be checked.