Maintain water's condition according to
VDI [Association of German Engineers]
2035 "Prevention of damage in water heat-
ing installations".
Observe limitations of use in damp loca-
radiators".
Use radiator only in closed heating systems.
Store and transport radiator only in the
protective packaging.
Make allowance for minimum clearances
between the radiator and adjacent parts
for air circulation: 50 mm.
For electrical accessory operation:
Take protective areas according to DIN VDE
0100-701 into account. Also follow all local
regulations.
Operate the heating element only with the
voltage approved (see rating plate).
Complaint
Contact the supplier.
Disposal
Packaging and any parts that are not need-
ed should be recycled or disposed of prop-
erly. Observe local regulations.

Technical features

Operating pressure: max. 6 bar
Test pressure: 7.8 bar
Flow temperature:
Hot water up to 110 °C (230 °F)
for electrical accessory operation up to
80 °C
Electrical connection (for electrical acces-
sory operation):
Heating element preinstalled on the ra-
diator at the bottom right or left
Connection via electric set
Heating element for IDV10 cannot be
6
Installation
With the heating element (IDV11) installed po-
sition the radiator in such a way that the cable
is not kinked or damaged.
Preliminaries (see Fig. 1–9)
For electrical accessory operation make sure
that a connector socket (230 V, fuse protec-
tion 16 A) installed according to regulation
is present within the range of the cable.
Check the delivery for completeness and
damage.
Preposition requisite tools.
When installing, only remove protective
packaging at the fastening and connection
points.
the return (RL [return] - top hole free) is on the
right ex works (see Fig. A).
set screws on the connecting pieces.
Screw the converter tightly onto the con-
necting pieces.
Screw the air vent plug in.
Screw long fastening screws into the upper
sleeves and tighten.
Screw spacer bolts into the lower sleeves
and tighten.
For electrical accessory operation: Tighten
the heating element with 20 Nm tighten-
ing torque.
If any accessories are supplied, e.g. towel
rod, install (see separate instructions).
Mark drilling positions (see Fig. A).
Drill holes and seat dowel.
Screw the lock screws in the wall brackets
out and pull the holders out.
Fasten the wall brackets with Allen screws.
On doing so pay attention to the position
of the hole.
Insert the holders in the wall brackets. On
doing so pay attention to the position of
the openings.
Fasten the holders with the lock screws just
be adjusted for alignment.