S I N T E R I N G P R O G R A M S
6

Sintering programs

E N
The operating display is designed as a
touchscreen. For operation, the corre-
sponding symbols on the display must be
touched.
6.1

Program overview

The high-temperature sintering furnace has a per-
manently stored program for sintering zirconium
oxide frameworks for various indications. Further
programs for sintering, glazing or drying of dental
oxide ceramics can be freely programmed within
the permissible program parameter limits and
stored at free program locations.
Several programs for Amann Girrbach materials
are already pre-installed on the furnace These
programs should not be changed.
6.2
Programming the sintering pro-
gram
Information/tips on programming / controller
behaviour:
_ A program can consist of up to eight segments.
_ The parameters heating rate, target tempera-
ture and dwell time can be assigned to each seg-
ment.
_ To protect the furnace system against over-
heating or overloading, these parameters may
be limited.
_ When parameters are exceeded during input,
the furnace displays them as red lines in the
graph of the editing level. In this case, the pro-
gram cannot be saved.
36
Programming a program:
▷ Tap the
button.
The program list is displayed.
P1
High speed dry
P1 High speed dry
P2
P3
P4
P5
30°C
Standby
Fig. 10 Program list
▷ If required, scroll to an empty program assign-
ment location with the
▷ Tap on an empty program assignment location
or to a program to be changed.
The window for editing a program is displayed.
P2
Speed FX
1600
1200
800
400
0
20
40
60
80
+
30°C
Standby
Fig. 11
Editing a program
▷ Tap on the desired segment or select using the
and
buttons.
▷ Tap on the parameter for the selected segment
and enter the desired value with the numeric
keypad.
= Heating rate
= Target temperature
= Dwell duration
▷ Tap on another segment or select using the
and
buttons.
00:00
and
buttons.
60
°C/min
0 %
990
°C
0
min
1