Specifications . Installation
Specifications
Power supply required...................................115V, 60 HZ.
Liquid Temp. Range..........................32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.).............15 Amps
Discharge:........................................................ 1-1/2" NPT
NOTICE Do not reduce size of discharge pipe or hose
below 1-1/4" diameter. If discharge is too small, pump will
overheat and fail prematurely.
Float Switch Installation
Models equipped with vertical switches require some
assembly. Models with tethered float switches are ready
for use.
For parts or assistance, call Master Plumber Pump Customer Service at 800-628-9439
This pump is designed for use in a residential sump only.
Only pump water with this pump.
NOTICE This unit is not designed as a waterfall or fountain
pump, or for applications involving salt water or brine!
Use with waterfalls, fountains, salt water or brine will void
warranty.
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.
Installation
1.
Install pump in sump pit with minimum diameter of 10"
(254mm) for models equipped with vertical switches
and 14" (356mm) for tethered float switch models.
Sump depth should be 18" (457mm) for tethered
models and 13" (330mm) for vertically switched
models. Construct sump pit of tile, concrete, steel or
plastic. Check local codes for approved materials and
for proper installation.
2. Install pump in pit so that switch operating
mechanism has maximum possible clearance.
3. Pump should not be installed on clay, earth or sand
surfaces. Clean sump pit of small stones and gravel
which could clog pump. Keep pump inlet screen clear.
NOTICE Do not use ordinary pipe joint compound on
plastic pipe. Pipe joint compound can weaken plastics.
6765 0213
3
4827 0205