8.2 Device does not lift to maximum height
• Check the oil level (see 7.4).
8.3 Device does not lift with first stroke
• Press the lowering pedal with your right hand whilst performing
some rapid pump movements with your left hand.

8.4 Pump does not build up pressure

• Remove the vent plug.
• Place a clean cloth (folded in two) over the opening.
• Introduce compressed air into the tank with an air gun whilst
simultaneously performing some rapid pump movements.

8.5 Malfunctions / valve maintenance

The valves used normally require no maintenance. Please
refer to sections 1-4 under Troubleshooting if the pump
malfunctions.
If the tests listed therein do not remedy the problem, please
send us the pump for repair.
Operating instructions
Vent plug
Pressure control valve
Pump pedal
Lowering pedal
Hose connection