Fitting Instructions workbook
LPG level gauge sensor suitable for
TOMASETTO multivalve
Cod. 763Ni - 763N
FOR MULTIVALVES
WITH ORIGINAL POINTER
PIN OF 4,3 mm
1) Remove the slide and original pointer of
the multivalve and replace them with the
ones supplied in the A.E.B. package. Insert
the pointer with the shorter pin (4.3 mm)
using the same magnet, paying attention not
to invert the polarity. If installation is done on
a 0° multivalve the magnet must be
positioned as in Figure 1 , whereas on a 30°
one position the magnet in the middle as in
Figure 2 .
In both cases, moving the magnet further to
the right delays the reserve LED coming on,
moving the magnet further to the left makes
the reserve LED come on sooner.