Hurricane Haze 2D QRG
AC Power
Fuse Replacement
Fluid Tank
Indicator Lights
This product has a fixed voltage power supply and it can work with an
input voltage of either 120 V, 60 Hz or 230 V, 50 Hz, depending on the
specific model.
To eliminate wear and improve its lifespan, during periods of non-use
completely disconnect from power via breaker or by unplugging it.
1.
Disconnect the product from power.
2.
Wedge the tip of a flat-head screwdriver into the slot of the fuse
holder.
3.
Pry the safety cap out of the housing.
4.
Remove the blown fuse from the clip on the front of the safety cap and
replace with a fuse of the exact same type and rating.
5.
Re-insert the fuse holder and reconnect power.
Three indicator LEDs show the status of the fill tank, as follows:
· Red - the fluid tank is currently heating up
· Blue - the fluid tank is ready
· Flashing Blue - the fluid tank requires refilling
Note: The Hurricane Haze 2D may be operational while the fluid tank
is heating.