K7127 Ref.Detect. O/M
6/3/01
This manual refers to RBC-RD1-PE & RBC-RD2-PE models.
These refrigerant detectors are only for use with R407C refrigerant.
The RD1 is for indoor refrigerant detection only, it can be used on any MMS indoor
or any RAV '4' Series AI indoor unit.
The RD2 is for the MMS outdoor unit only.
The sensor element is sensitive to other gases/vapours other than R407C, do not
spray any aerosols or similar substances near or directly at the sensor housing. Do not
use solvent cleaners in proximity to the detector.
Do not cover or restrict the air flow over the sensor by obstructing the vents, for
example, with furniture.

Model Differentiation

G
There are two models available, the first is RBC-RD1-PE. The RD1 is designed to be
installed next to the indoor unit, with the remote sensor and audible alarm located at
a low level and preferably under the indoor unit.
G
The RD1 is designed for use with MMS indoor units and RAV '4' Series AI indoor units
only.
G
The second model is the RBC-RD2-PE. This model (RD2) is designed for use in the
modular multi outdoor unit. The unit will be located within the compressor housing,
and it has an internal sensor.
G
The RD2 can only be fitted to the MMS outdoor unit only.
G
The functionality of both systems will be covered in indoor & outdoor operation section
of this manual.