FIXTURE OPERATION
FIXTURE OPERATION
FIXTURE OPERATION
1. DAYLIGTH SENSOR ADJUSTMENT
If your model has an adjustable daylight sensor (PE models)
position dial to allow lights to activate during daytime. Once you
adjusted Brightness and Light Color re-position your dial for dusk-
to-dawn/night time operation.
SET DAYLIGHT SENSOR DIAL
2. AIM LAMP HEADS
Gently grasp lamp heads (B) and position in desired directions.
CAUTION - Risk of Shock: Aim lamp heads at least 20° down
below horizontal in order to prevent water from accumulating
inside lens.
3. BRIGHTNESS LEVEL SETTING
Fixture is preset to full brighness indicated by the larger sun icon
above the DIM dial. If lower brighTness is desired set DIM dial to
small sun icon.
SET BRIGHTNESS DIAL
Set dial
here for dim
brightness
4. LIGHT COLOR SETTING
Note: Light color is not adjustable for Accent light, the adjustment
is only for lamp heads.
•
Set dial to desired light color
SET LIGHT COLOR DIAL
choose your light color
WARM
Set dial in this position
to allow lights to
activate in daytime
Set dial in this position to
activate when there is more
surrounding ambient light
Set dial in this position for
dusk-to-dawn operation to
activate using less ambient
light
Set dial
here for full
brighness
DAYLIGHT
COOL
TROUBLE SHOOTING GUIDE
Trouble Shooting Guide
If this fixture fails to operate properly, use the guide below
to diagnose and correct the problem.
•
Verify that power is turned on at switch and breaker
•
Verify that fixture is wired properly
•
Verify that line voltage is correct (120V)
Test if Daylight Sensor works properly:
The Daylight Sensor in the "PE" models is designed to turn on the
fixture light at low light levels (Dusk to Dawn) and has a rotatable
cover to allow adjustment of light entry.
If light does not come on or stays on:
•
Close Sensor (Blue window) - Light should come on.
•
Open Sensor (clear window) and shine a flashlight into
Photocontrol - Light should go off
If fixture cycles on and off:
Light reflecting back off any surrounding surfaces, or from other
light sources enters the daylight sensor. To correct problem,
eliminate reflective surfaces, turn the rotatable cover to reduce
the opening or reposition the Light fixture.
If Photocontrol cover is in closed position, it will allow continuous
operation of fixture during daylight.
If further technical assistance is required, contact: Technical
Support at: (800) 705-7378
This LED light provides low maintenance service with no bulbs
to change. Clean surfaces with mild soap and water. Do not use
abrasive materials such as scouring pads or powders, steel wool
or abrasive paper.
WARNING: There are no user serviceable parts inside fixture.