FBM L / LS
properly engaged (see figure 17).
8 - On FBM 1P model install the lateral tray by reversing the
disassembly steps (see figure 6).
9 - Use fresh product to chase any remaining sanitizer from
the bottom of the bowl(s). Drain this solution. Do not rinse
out the machine.
5. 4 IN-PLACE SANITIZATION
The In-Place Sanitization prior to starting the machine may
be performed, if needed, only as further precaution, in
addition to the Disassembled Parts Sanitization described
before, but never in lieu of it.
1 - Prepare two gallons of a warm (45-60°C, 120-140 °F)
sanitizing solution (100 PPM chlorine residual) according
t o y o u r l o c a l H e a l t h C o d e s a n d m a n u f a c t u r e r ' s
specifications.
2 - Pour the solution into the bowl(s).
3 - Using a brush suitable for the purpose, wipe the solution
on all surfaces protruding above the solution-level and on
the underside of the top cover(s).
4 - Install the top cover(s) and operate the unit. Allow the
solution to agitate for about two minutes. Drain the solution
out of the bowl(s).
5 - Use fresh product to chase any remaining sanitizer from
the bottom of the bowl(s). Drain this solution. Do not rinse
out the machine.
6 ROUTINE MAINTENANCE
ATTENTION
In case of damages, the power cord must be replaced
by qualified personnel only in order to prevent any
shock hazard.
1 - Daily: inspect the machine for signs of product leaks past
seals and gaskets. If proper assembly does not stop leaks
around seals or gaskets, check for improper lubrication,
worn or damaged parts. Replace parts as needed.
2 - Monthly on FBM 1P, FBM 2 and FBM 3 models: remove
the dust from the condenser filter. A blocked filter will
ATTENTION
Before any disassembly and/or cleaning procedure
make sure that the dispenser is disconnected from its
power source by unplugging it or switching off the 2-
pole wall breaker.
18
figure 17
reduce performance and could cause compressor failure.
Remove the only left panel (from faucet side) unscrewing
the two plastic coated screws (see figure 18).
ATTENTION
Condenser fins are very sharp. Use extreme caution
when cleaning.
3 - Replacement of lighted top cover bulb: remove the fixing
screw placed in the upper part of the top cover, remove the
lower part and replace the bulb (using a 24-28V 21W max
bulb). Reassemble the top cover and replace the fixing
screw.(see figure 19)
6. 1 MAINTENANCE (TO BE CARRIED OUT
BY QUALIFIED SERVICE PERSONNEL
ONLY)
1 - Monthly ONLY on FBM 1 model: remove the dust from
the condenser. To do this unplug the unit or switch off the
2-pole wall breaker and then remove the panels.
2 - Annually: remove the panels and clean the inside of the
machine including the base, side panels, condenser, etc.
3 - Never remove the insulating jacket from around the
suction tubing of the evaporator (the copper tubing located
on the right side of gear motor). In case the insulating
jacket is missing replace the entire parts with original
spare parts from the supplier.
4 - In order to prevent any damages to the dispenser, all
plastics parts must be lubricated only with grease supplied
by the manufacturer or with another lubricating product
suitable for polycarbonate.
IMPORTANT
The electric diagram of the dispenser is located in the
inner part of the dispensing side panel.
figure 18
figure 19
Bras Internazionale spa