TROUBLESHOOTING GUIDE

PROBLEM
Engine will not
1.
start
2.
3.
4.
5.
6.
7.
1.
No electrical
output
2.
3.
4.
5.
Repeated
1.
circuit breaker
2.
tripping
Generator
1.
overheating
2.
1.
No auto idle
2.
3.
4.
5.
DC does not
1.
have power
with the
2.
circuit breaker
depressed
3.
D29833
CAUSE
Low on fuel or oil.
Ignition switch in "Off"
position.
Faulty spark plug.
Choke in wrong position.
Fuel shut-off valve in
closed position
Unit loaded during start-
up.
Spark plug wire loose.
Faulty receptacle.
Circuit breaker kicked
out.
Defective capacitor.
Faulty power cord.
GFCI switch breaker
kicked out
Overload
Faulty cords or
equipment
Generator overloaded.
Insufficient ventilation.
Faulty solenoid
Faulty idle control switch 2.
Faulty windings in stator
Faulty circuit board
Faulty wire harness
Faulty rectifier
Faulty windings in stator
Faulty wire harness
20- ENG
CORRECTION
1.
Add fuel or oil.
2.
Turn to "ON" position
3.
Replace spark plug.
4.
Adjust choke accordingly.
5.
Open fuel shut-off valve.
6. Remove load from unit.
7. Attach wire to spark plug.
1. Have Service Center
replace.
2. Depress and reset.
3. Have Service Center
replace capacitor.
4. Repair or replace cord.
5. Depress and reset
1.
Reduce load.
2.
Check for damaged, bare,
or frayed wires on
equipment. Replace.
1. Reduce load.
2. Move to adequate supply
of fresh air.
1. Have Service Center
replace.
Have Service Center
replace.
3. Have Service Center
replace.
4. Have Service Center
replace.
5. Have Service Center
replace.
1. Have Service Center
replace.
2.
Have Service Center
replace.
3. Have Service Center
replace.