2.6 Gas requirements
Ensure that the requirements for the gas supply are met.
The cooktop is shipped from the factory for use with natu-
ral gas. For use with LP conversion, a certified technician
or installer must do the conversion.
Supply pressure:
¡ Natural Gas: 7 inches water column (17.4 Millibars)
¡ Propane Gas: 11 inches water column (27.4 Millibars)
¡ The propane gas tank must be equipped with its own
high pressure regulator in addition to the pressure regu-
lator supplied with this unit.
2.7 Electrical requirements
Ensure that the following electrical requirements are met.
CAUTION
Do not use an extension cord with this appliance.
¡ This appliance requires a 60 Hz, 15 Amp, 120 V/AC
connection.
¡ The appliance is equipped with a 40" (1000 mm) power
cord.
¡ The power connection must remain accessible from the
front of the cabinet after the installation is complete.
3 Prepare installation space

Prepare installation space

Create the cutout in the countertop according to the in-
Prepare installation space
structions.
General countertop requirements:
¡ The angle of the cut surface to the countertop must be
90°.
¡ With multi-layered countertops, secure strips laterally in
the cutout if necessary.
¡ After creating the cutout, remove all shavings.
¡ Seal the cut surfaces in a heat- and water-resistant
manner.
¡ If there is no oven beneath the cooktop, install a non-
combustible floor with a 3/8" (10 mm) space between
the floor and the bottom of the cooktop. The distance
from the intermediate floor to the power supply connec-
tion for the appliance must be at least 3/8" (10 mm).
¡ Observe the minimum distance between device under-
side and cabinet surfaces of ⅜" (10 mm).
3.1 Dimensions for 30" cooktops
Refer to these measurements for the models stated here.
¡ NGMP058UC
8
min. ¾" (19)
max. 2" (50)
*For installation in a kitchen island.
3.2 Dimensions for 36" cooktops
Refer to these measurements for the models stated here.
¡ NGMP658UC
min. ¾" (19)
max. 2" (50)
2⅜"
(60)
2⅜"
(60)