Panasonic CU-RE9JKX Instrucciones De Operación página 7

Ocultar thumbs Ver también para CU-RE9JKX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
TROUBLESHOOTING
TROUBLESHOOTING
The following symptoms do not indicate malfunction.
The following symptoms do not indicate malfunction.
Symptom
Symptom
Mist emerges from indoor unit.
Water fl owing sound during operation.
The room has a peculiar odour.
Indoor fan stops occasionally during automatic
fan speed setting.
Operation is delayed a few minutes after
restart.
Outdoor unit emits water/steam.
The unit operates automatically when power is
resumed after a power failure.
Power indicator blinks during operation and
the indoor fan is stopped.
Indoor fan stops occasionally during heating
operation.
Power indicator blinks before the unit is
switched on.
Cracking sound during operation.
Check the following before calling for servicing.
Check the following before calling for servicing.
Symptom
Symptom
Heating/Cooling operation is not working
effi ciently.
Noisy during operation.
Remote control does not work.
(Display is dim or transmission signal is weak.)
The unit does not work.
The unit does not receive the signal from the
remote control.
The unit stops and the timer indicator blinks.
The unit stops and the timer indicator blinks.
Use remote control to retrieve error code.
Press for 5
1
seconds.
4
Turn the unit off and reveal the error code to authorized dealer.
F566761_EN1.indd
F566761_EN1.indd
章节2:7
章节2:7
All manuals and user guides at all-guides.com
Cause
Cause
• Condensation effect due to cooling process.
• Refrigerant fl ow inside the unit.
• This may due to damp smell emitted by the wall, carpet, furniture or
clothing.
• This helps to remove the surrounding odours.
• The delay is a protection to the unit's compressor.
• Condensation or evaporation occurs on pipes.
• It is the Auto Restart function of the unit. Operation will be restarted
automatically under the previous operation mode and airfl ow direction
when power is resumed as the operation is not stopped by remote control.
• To cancel the Auto Restart Control, please contact with authorized
distributor.
• The unit is in defrost mode, and the melted frost is drained from the
outdoor unit.
• To avoid unintended cooling effect.
• This is a preliminary step in preparation for the operation when the ON
timer has been set.
• Changes of temperature cause the expansion/contraction of the unit.
Check
Check
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet vents.
• Check if the unit has been installed at an incline.
• Close the front panel properly.
• Insert the batteries correctly.
• Replace weak batteries.
• Check if the circuit breaker is tripped.
• Check if timers have been set.
• Make sure the receiver not obstructed.
• Certain fl uorescent lights may interfere with signal transmitter. Please
consult your nearest dealer.
Press until you hear
2
beep sound, then jot
POWERFUL / QUIET
POWERFUL / QUIET
down the error code.
Press for 5 seconds
3
to quit checking.
SET/CANCEL
SET/CANCEL
SELECT
SELECT
CHECK
CHECK
ERROR
ERROR RESET
RESET
RESET
RESET
NOTE :
NOTE :
• For certain error, you may
restart the unit with limited
operation with 4 beeps
during operation starts.
2008-12-10
2008-12-10
7
8:47:41
8:47:41

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cs-re12jkxCu-re12jkxCs-re15jkxCu-re15jkx

Tabla de contenido