Kunzer MPB 12-24/2000 Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
HOW TO CHARGE THE EMERGENCY STARTER
CAUTION: charge the Emergency Starter for at least 8 hours immediately after purchase and each
time that it is used. If the Emergency Starter is not in use, recharge it at least every 3 months to
maintain the internal battery in perfect working order.
Charging the emergency starter using the 230VAC charger
1. Make sure that no appliance is connected to the Emergency Starter. Use the TEST button to check
the charge level on the voltmeter (red, battery at 30% - yellow, battery at 60% - green, battery at
100%). If the voltmeter gauge does not reach green, charge the battery of the Emergency Starter.
2. Insert the plug of the 230V charger into the charging socket located on the front of the Emergency
Starter.
3. Insert the charger into the socket of the 230V domestic supply.
4. If the Emergency Starter is not in use, recharge it at least every 3 months for 8 hours to maintain the
internal batteries in perfect working order. The battery charger of the Emergency Starter is automatic,
so it can remain connected to the Emergency Starter permanently when it is not in use.
CAUTION: Use only the charger provided.
CAUTION: If you decide to stop the charge before is completed (Full), swich OFF the booster
HOW TO USE THE EMERGENCY STARTER
Using the Emergency Starter to start up vehicles
1. Always wear safety goggles and keep your face away from the battery when connecting it.
2. Check that the emergency starter is in the OFF position.
3. Check the voltage of the vehicle battery.
CAUTION: VOLTAGE INCOMPATIBILITY BETWEEN THE EMERGENCY STARTER AND THE
VOLTAGE OF THE VEHICLE'S ELECTRICAL SYSTEM CAN CAUSE EXPLOSIONS AND
DAMAGE THE VEHICLE, PRODUCT AND PEOPLE.
4. Identify the pole corresponding to the earth of the vehicle; this is generally connected to the
negative terminal.
5. CAUTION: never switch polarity. Always connect the output conductor with a red battery clip
(+) to the positive pole of the battery and the output conductor with a black battery clip (-) to
the vehicle's earth (ground). CAUTION: INVERTING POLARITY CAN CAUSE EXPLOSIONS,
DAMAGE THE VEHICLE, PRODUCT AND PEOPLE.
CAUTION: if the LED RED / REVERSE is set on, the polarity has been reversed. Disconnect the
battery clips from the vehicle and connect them correctly.
CAUTION: check that the cables of the Emergency Starter are far away from fans, from moving parts
and from the fuel conduit.
6. Now PRESS "START/STOP" button blue led lit on and display show "STRT".
7. The led lit in correspondence of the detected voltage (12V or 24V).
8. If the detected voltage is 12V, but the battery is 24V, please use the "OVER RIDE" function.
(Remove the clips and follow the OVER RIDE FUNCTION procedure)
9. Once the vehicle has been started up, emergency starter automatically turns off after 30 seconds.
Otherwise press START/STOP button to turn off the emergency starter .
10. Disconnect the output conductor with the black battery clip from the earth of the vehicle and
replace output conductor with the black battery clip in its housing.
11. Disconnect the output conductor with the red battery clip from the positive terminal (+) of the
battery and return it immediately to its seat.
CAUTION: if you are unable to start the vehicle within 5 seconds, do not continue with the starting
attempt. Before trying to start up the vehicle again, let the Emergency Starter rest for at least 3
minutes to avoid damaging the appliance.

Publicidad

Tabla de contenido
loading