Flow Rate Chart
35º F Temp Rise - 0.6 GPM
45º F Temp Rise - 0.5 GPM
Troubleshooting
PROBLEM ISSUE
Water not hot
enough.
Water too hot.
7
POSSIBLE CAUSE
Too much water flowing
through the heater.
Reduction in the ambient
temperature.
Water Pressure below of
0.5 bar (7 psi).
Electrical Malfunction.
Not enough water flowing
through the heater.
Increase in the ambient
temperature.
SOLUTION
Reduce the flow rate of the water via
the outlet tap.
Switch to higher temperature setting.
Check if the main water line stop
valve is fully open and that there
are no other restrictions in the water
supply line.
Have the Heater unit check by a
qualified eIectrician or contact your
local authorized distributor.
Increase the flow rate via the outlet
tap.
Switch to lower temperature setting.