Troubleshooting
PROBLEM ISSUE
Heater shut off
during use.
Water ceases to
flow.
Water temperature
varies from hot to
cold during use.
No hot water/Unit
is not working.
If you have an issue and need further assistance,
POSSIBLE CAUSE
Interruption of main
electrical supply.
No water supply.
Water pressure has
dropped below min. level.
No electrical power.
Low flow rate 0.5 bar (7 psi).
please call: 1-888-783-6082
SOLUTION
Check incoming power supply, MCB,
switches and supply cabling.
If problem persists, call your local
manufacturer for assistance.
Check if the main water line stop
valve is fully open and that there
are no other restrictions in the water
supply line.
Increase hot water supply.
Check the circuit breaker and check
voltage at the wiring block.
Clean filter screen:
1. Turn circuit breaker off.
2. Open the valve to release pressure
from the unit.
3. Turn circuit breaker on.