Self-Test Function - LaserLiner DampFinder Manual Del Usuario

Ocultar thumbs Ver también para DampFinder:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22

Self-test function

4
1.
Measurement procedure notice
Be sure neither supply lines (electric lines, water pipes, etc) nor a
metal subsurface is present at the location to be measured. Insert
the electrodes as far into the material as possible but never use
excessive or sudden impact force as this could damage the unit.
Always pull the unit out of the material with left/right twisting
motion. Perform several comparative measurements at
different locations to minimise measurement error. The sharply
pointed electrodes present an injury hazard. Always put the
safety cap on the unit when it is not in use or being transported.
Wood
5
The location to be measured
should be untreated, free of
knots, dirt and resin.
Measurements should not
be made on the end faces of
wood because these areas
dry particularly quickly such
that they produce incorrect
measurement results.
Read measurement results
from the left-hand wood
moisture scale.
Refer to the conversion table
below in order to obtain more
precise measurements for
different materials.
2.
+
Mineral building materials
Be aware that walls (or sur-
faces) made of several different
materials, or even variations in
the material's consistency, can
cause measurement results to
be falsi ed. Perform multiple
comparative measurements.
Read measurement results
from the right-hand building
materials scale.
Refer to the conversion table
below in order to obtain more
precise measurements for
different materials.
DampFinder
1.
2.
07
GB

Publicidad

Tabla de contenido
loading

Tabla de contenido