74
Advanced programming
By using advanced programming, you can customize the signal pattern from a specific
transmitter and event, displaying the LED colour and vibration pattern of your choice. The ad-
vanced programming overrides the radio key and pairs the units via the serial number. Please
note that smoke alarms cannot be programmed for safety reasons.
Note: The transmitter must be activated as it is intended to be used in the system to generate
the right signal.
This means that you can't always use the transmitter test button (see Default signal pattern
for the relevant transmitter).
Here is how you program the receiver:
1 Press and hold the mute/test button on the receiver. The green and yellow Visit LEDs will
start to blink alternately. While still holding down the button, activate the desired trans-
mitter as intended. Release the button.
2 Scroll through the different Visit LED options by pressing the mute/test button on the
receiver. Select the desired Visit LED colour by holding down the mute/test button until
the power LED goes out and lights up again.
3 Scroll through the different vibration options by pressing the test button on the receiver
(bed shaker required). Select the desired vibration pattern by holding down the mute/test
button until the power LED goes out and lights up again.
4 The receiver will now show the new Visit LED colour and vibration pattern. Press the mute/
test button briefly to end the demonstration. After a short while, it will return to normal
mode.
Deleting the advanced programming
Follow the procedure below to delete the advanced programming.
1 Hold down the mute/test button on the receiver until the green and yellow Visit LEDs
blink alternately. Release the button.
2 Press the mute/test button on the receiver 3 times in quick succession.
3 All Visit LEDs will light up for ~2 seconds to show that it has been deleted.
Testing
It is easy to test the flash receiver. If it does not work as described below, see the section
Troubleshooting.
Testing the system
A Visit transmitter set to the same radio key as the flash receiver is required to test the
system. You will need a bed shaker accessory to test the vibration.
1 Press the transmitter test button.
2 The flash receiver will:
- Start to flash
- Light up the corresponding Visit LED
- If a bed shaker accessory is connected, it will start to vibrate
Testing the landline telephone connection
1 Connect the flash receiver to an analogue telephone socket via the telephone Input.
You will need a telephone flex cable accessory and an adapter plug accessory.
2 Use for instance your mobile phone to call your landline telephone.
The flash receiver will start to flashing and light up the yellow Visit LED.
If a bed shaker accessory is connected, it will start to vibrate.
To repeat the last indication, press the flash receiver test button.