3.0 PROTECTION
When OPP, OVP,OTP or short protection is triggered, the main outputs will be
latched off. The main outputs can be reset by cycling the DC remote on/off or
AC power. +5Vsb output is auto recovery when fault condition removed.
3.1 OVER POWER PROTECTION
Foldback at 115%~150% over peak load
3.2 OVER VOLTAGE PROTECTION
+3.3V output
+5.0V output
+12.0V output 16 Vmax.
3.3 SHORT PROTECTION
All output to GND.
3.4 Over Temperature protection
4.0 ENVIRONMENT:
4.1 OPERATING TEMP.
4.2 STORAGE TEMP.
4.3 OPERATING HUMIDITY
4.4 STORAGE HUMIDITY
4.5 OPERATING ALTITUDE
4.6 STORAGE ALTITUDE
5.0 HI-POT:(Input/Output isolation)
5.1 PRIMARY TO SECONDARY
3535Vdc for 3 seconds
5.2 INSULATION RESISTANCE
Primary to earth ground 500Vdc , 50M ohms Min.
05
5.2 Vmax.
7.0 Vmax.
0 ºC to +40 ºC
-20 ºC to +70 ºC
20% to 90%,non-condensing
5% to 95%, non-condensing
0 to 10,000 feet
0 to 50,000 feet