In power supply conditions higher than 240 V A/C, the
"HI" high voltage regulator (2) is that which will operate as
switch when it is set leftwards to the limit.
GENERAL INSTRUCTIONS FOR USE
4.
Put the machine into operation and adjust it in accordance
with the above instructions. Connect the equipment to be
protected to the output of the OVERCONTROL. Turn on
the equipment to protected.
Operation is automatic.
When a hazardous situation arises, OVERCONTROL will
cut off the power supply until the hazardous situation has
disappeared or for a minimum 2 sec alert period.
At the same time power supply has been cut off, the
display screen will show a value of 002 to 004 to alert on
the power cut-off due to start of the protection.
The two setting regulators cover a very broad range of
voltages for protecting against both voltage drops and
overvoltages.
Regulate in accordance with your needs, starting from
points "W" in the case of welding units and from a point
between "W" and "MAX" for optimum protection for the
rest of the equipments.
In environments where there are bad power supply,
imperfect generators or environments with high electrical
noise, but it is indispensable to work, protection may be
reduced by advancing regulators (1 and 2) to their "MIN"
protection positions.
The 3-digit 7 segment display high-brilliance LED screen
(3) shows the value of the voltage supplied to the input of
the OVERCONTROL.
In the case of high consumption of a low-quality installation
or with a long extension cord and having sections of less
than 2.5 mm², (even worse when the extension cord
is rolled up), or a bad or little powerful generator, large
voltage drops may be confirmed on the screen.
It is reminded that relevant voltage drops are also
dangerous and that OVERCONTROL informs you on that
situation and offers the protection cut-off setting from 140
V A/C onwards.
IMPORTANT: Both, the plug (4) to which OVERCONTROL
is connected and its plug (5) and power output are of the
SCHUKO type and certified for a maximum intensity of 16
ampere RMS flowing therethrough.
However, the capacity of the OVERCONTROL circuit is
40 amperes RMS, sufficient for a high-power equipment
or installation of up to 9 KVA.
Despite the good design of the SCHUKO connectors
and the generalized abuse much above 16 amperes, the
abuse of these connectors above 16 amperes is neither
lawful nor recommended.
Contact your STAYER distributor regarding the migration
to professional connectors (for example IEC60309) if you
are going to work at high power.
SERVICING AND MAINTENANCE INSTRUCTIONS
5.
The equipment does not require any special maintenance.
Keep OVERCONTROL clean, dry and without shocks.
ENGLISH
11
Disconnect OVERCONTROL and remove its cover from
time to time, and clean its inside by blowing compressed
air.6.1 Regulatory Marking (technical features)
Corporate name
Nominal voltage
Nominal withstand current
Maximum withstand current 40 amperes RMS on nominal voltage
Adjustable protection range
Fixed protection range
Nominal consumption of
equipment
Performance of the
equipment
Solid/liquid protection
Power cord, length
Power cord, section
Power cord, class
Power plug, input
Power outlet
Screen (display), type
Screen (display), precision

Repair service

The customer service will provide you with advice on your
eventual inquiries regarding repair and maintenance of
your product as well as on spare parts.
You may also obtain exploded view drawings and
information on the spare parts on the internet under:
info@grupostayer.com
Our team of technical advisors will be happy to advise you
in respect of the acquisition, application and settings of
the products and accessories
11
STAYER IBÉRICA, 28320 PINTO,
SPAIN
230V 50Hz-400Hz
16 amperes RMS on nominal voltage
LO: 140V-240, HI: 24OV-300V
Over 300V, 50Hz-400Hz
50W
99.98%
IP20
2.1m
3x2.5mm²
H07RN-E 3G2, 5mm2 450/750V
Schuko EEC 7/7
Schuko EEC 7/4 IP44
3-digits, high brilliance LED
+/- 4%