Technical data LOGO! 12/24 RCE Basic (continued)
Digital outputs
Number
Type of outputs
Electrical isolation
In groups of
Control of a digital output
Output voltage
Continuous current I
Incandescent lamp load (25,000 switching cycles) at
Florescent tubes with ballast
(25,000 switching cycles)
Conventional florescent tubes, compensated
(25,000 switching cycles)
Florescent tubes, uncompensated (25,000 switching cycles)
Derating
Short-circuit proof, cos 1
Short-circuit proof, cos 0.5 – 0.7
Parallel connected outputs for increased power
Fusing of an output relay (if desired)
Switching frequency
Mechanical
Ohmic load / lamp load
Inductive load
Subject to change without notice
Please refer to the LOGO! 8 manual for further information.
24
(per terminal)
th
4
Relay outputs
Yes
1
Yes
24 V DC
Maximum 10 A per relay
1000 W
10 x 58 W
1 x 58 W
10 x 58 W
None; within overall temperature range
Power protection B16, 600 A
Power protection B16, 900 A
Not permissible
Maximum 16 A, characteristic B16
10 Hz
2 Hz
0.5 Hz
© Festo Didactic 8045497