75816-39
DIGITAL THERMOSTAT WITH DISPLAY
Comfort / saving / security
temperatures selection button
and return to previous option
button.
Menu access button.
Confirm flashing value.
INSTALLATION
GB
This device is designed for installing in a universal flush mounting box
or surface mounting box. Follow diagram 1 for installation.
RECOMMENDATIONS
•
The installation should be carried out by an officially authorised technician.
Do not install near inductive charges (motors, transformers...).
A separate power supply line is advisable (if necessary from a network filter).
The assembly of the equipment must be independent, so that it remains clear of obstacles
and is not affected by other devices or other heat sources
RESET
•
The reset is done by simultaneously pressing the 4 keys for more than 3 seconds.
The factory default configuration after the reset is shown below:
Language: Spanish, Date and Time: 01/01/2006 00:00 (24 hr timetable mode).
Season changes: last Sunday of March at 02:00; last Sunday of October at 03:00.
Reference Temperatures: COMFORT (22 ºC), SAVINGS (17 ºC) Heating Mode.
Correction of the Temperature probe: 0.0 ºC.
DISCONNECT POWER
After cutting off the power supply, the equipment will recover the last valid
configuration prior to the loss of the power supply.
The programs and configuration parameters will be saved independently of the
time that the equipment is disconnected.
The equipment maintains the date and time during a 24 hr period without any type
of power supply. In the case of a longer power cut-off, it will be necessary to
program the device's date and time again by means of the CLOCK menu.
NOTE 1: When a power supply cut-off occurs, the output relay status (OFF) and
the ambient temperature measurement (25 ºC) is initiated by default. In the following
minute, the value of the ambient temperature and the output status will be updated
according to the scheduled program.
NOTE 2: When it receives power for the first time or after a prolonged disconnection, the
temperature measurement will take approximately 1 hour to achieve the specified precision
(±0.5 ºC). This is the approximate time period in which the device reaches the stable or
thermal system status.
OPERATION
The following information is displayed on the screen:
- Weekday.
- Time and date.
- Room temperature.
- Temperature setting and symbol corresponding to current period (comfort, saving,
anti-freezing/security).
The device is programmed using the menus and sub-menus.
The values to be programmed will flash on the display screen.
- Main screen: the thermostat shows the current date and uses the selected temperature
setting. This temperature can be modified by pressing
: Access the menu, validate a change by modifying and/or selecting comfort,
saving and anti-freeze/security temperature settings.
: Scroll up the menu / Increase the flashing value. If
can be increased faster, by 5 units per second
: Scroll down the menu / Decrease the flashing value. If
can be decreased faster, by 5 units per second.
c
: Return to the previous option or display the different temperatures on the screen.
Starting from the main screen, each time the button is pressed the following will
be displayed in order:
- COMFORT and the set temperature. Press
word COMFORT will be displayed. If no button has been pressed after 3 seconds,
it will return to automatic mode.
- SAVING and the set temperature. Press
SAVING will be displayed. If no button has been pressed after 3 seconds, it will
return to automatic mode.
- ANTI-FREEZING / SECURITY and the temperature setting (2ºC in heating mode and
55ºC in air conditioning mode). These temperatures cannot be modified. The word
ANTI-FREEZE or SECURITY will be displayed according to the selection. If no
button has been pressed after 3 seconds, it will return to automatic mode.
In the main screen, the thermostat displays the current date and time and uses the
selected reference temperature. This temperature can be modified by
key
pressing the
.
.
SIMON, S.A. Diputación, 390-392 / 08013 Barcelona
Atención Técnica al Cliente - Customer Technical Support:
Tel.902109700 E-mail:simonmail@simon.es http://www.simon.es
c
Increase/decrease temperature
buttons and function selection.
..
is held down the value
is held down the value
to change the temperature. The
. to change the temperature. The word
ELECTRONIC CONTROL DEVICES
L
N
Contact NC
normally open
Common
fig.1
Contact NA
normally closed
CLOCK MENU
The device's time can be set using this menu. The values to be configured include
(in this order): Year, month, day, weekday, hour, minute.
Once MINUTE has been confirmed the display will automatically return to the MAIN
MENU and the time and date will be saved.
LANGUAGE MENU
The language can be set using this menu, selecting between:
Spanish, English or Portuguese.
SETTINGS MENU
This menu accesses the more complex functions of the device, such as: correction
of temperature sensor, daylight savings changes, type of load, switch off mode and
configuration of the display light level.
- PROBE sub-menu
The correction to be applied to the probe can be set using this menu. Initially no
correction is established
(0.0ºC), but this can be corrected as required up to a value of ±5 ºC.
- LOAD sub-menu
The load on which the device will function can be set using this menu, selecting
between heating or air conditioning.
In HEAT mode, the "FLAME" symbol will be displayed when the room temperature
is lower than the set temperature.
In AIR CON mode, the "ICE" symbol will be displayed when the room temperature
is higher than the set temperature.
- SEASON sub-menu
In this menu the daylight savings changes can be set, selecting between:
AUTO: switches to daylight saving at 2am on the last Sunday in March and switches
back at 3am on the last Sunday in October.
MANUAL: this allows the specific dates and times of the changes to be established.
NOT USE: daylight saving changes will not be made.
- STATUS sub-menu
The device can be left without temperature programming.
ON: The temperature programming will function.
NUM DAY: The temperature timer programming will NOT function during the
established number of days, between 1 and 31 (for example: during holidays).
OFF: The temperature programming will NOT function.
- CONTRAST sub-menu
The level of brightness of the display (High/Low) can be selected using this menu.
- RELEASE sub-menu
The firmware version of the device can be displayed quickly in this menu.
Type: TRM V1.02.
TECHNICAL CHARACTERISTICS
- Power supply:
- Power supply tolerance:
- Frequency:
- Internal consumption:
- Anti-freezing Tº and safety:
- Temperature:
- Rupture capacity:
- Precision: =
- Temperature precision:
- Type of protection:
- Class of protection:
- Directives
MARK
2
1
4
L
N
75816-39
230 V~/ 50 Hz
8(2)A 250V~
u
0T40
R24h
230 V~
± 10%
50 Hz.
16.5 VA Maximum capacitives (1.4 W).
Anti-freezing (2ºC) and safety (+55 ºC)
from 0 ºC to +40 ºC
µ 8 (2) A / 250 V ac
± 1 s/24 h at 23 ºC using quartz crystal
± 0.5 ºC
IP 20 according to EN 60529
II according to EN 60335 fully installed
2002/95/EC (RoHS) 73/23/CEE
and 93/68/CEE (Electrical Safety)
89/336/CEE and 92/31/CEE (CEM)
CE