Installation Instructions – LAS Area / Site
Selectable Lumen Switch
Tools Required:
5mm Allen Wrench
Torque Wrench
Small Flat Head screwdriver (provided)
Ensure there is no power to the fixture prior to
N
ote:
adjusting the selectable lumen switch.
N
ote:
If for use with external controls system, follow
instructions below but remove dimming leads from
selectable lumen switch for use external to luminaire.
1.
Open the fixture door by loosening the three Allen head
screws. (Figure 1.) No need to completely remove the
Allen head screws, there is a rubber ring on each screw
to hold it to the housing door.
Figure 1.
2.
Using the provided small flat head screwdriver, adjust
the selectable lumen switch to the desired light level.
Nominal lumens in table below. For specific value by
optical distribution, refer to product specification sheet.
LAS45
Switch
Position
Lumens
0 (Factory
20,000
pre-set)
1
18,400
2
16,800
3
14,500
4
13,400
5
12,000
6
11,500
7
10,700
8
4,900
9
4,900
2
Cooper Lighting Solutions
Allen
Head
Screws
LAS100
HID
HID
Lumens
Equivalent
Equivalent
450W
34,000
400W
31,100
250W
28.400
250W
24,500
250W
22,600
150W
20,400
150W
19,500
100-150W
18,100
70W
8,300
70W
8,300
IB514101EN
Installation instructions
3.
Close and reinstall the door to the housing by
tightening the three Allen head screws to 30 in-lbs. Be
sure not to pinch any wires when closing the door.
Installation
Slipfitter Mounting Arm
Tools Required:
#2 Phillips screwdriver
4/5/6mm Allen wrenches
Torque Wrench
M15/M17 Socket Wrench
Drill (optional)
1.
Remove the cover plate on the slipfitter mounting arm
via two Phillips head screws and set aside. (Figure 2.)
No need to completely remove the four Phillips head
screws, there is a rubber ring on each screw to hold it
to the cover plate.
Figure 2.
2.
Route wire leads from luminaire into the slipfitter and
install slipfitter onto luminaire. Secure with two Allen
screws. Tighten to 30 in-lbs. (Figure 3.)
Be sure not to pinch wires between slipfitter and
N
ote:
luminaire.
1,000W
750W
750W
450W
450W
450W
450W
400W
-
Figure 3.
-
Phillips Screw
Phillips Screw
Allen
Head
Screws