13.- 100 V zone output terminals (COM - Z1 - Z2 - Z3 - Z4): terminals to connect the loudspeaker lines of
zones 1 to 4. To activate/deactivate the zones use the front switches. With the zone selection terminals
only loudspeakers with 100 V line transformer must be used. The total connected power of the
loudspeakers must not exceed that of the amplifier. Connect the positive of each zone to the
corresponding Z1 to Z4 terminal and the one common to all the zones to a COM terminal.
14.- LEVEL/MOH: monitor output volume control. Turning the control in a clockwise direction, increases
the volume and the opposite, reduces it.
15.- Aux loudspeaker output terminals 1 W 8 Ω - 600 Ω (Monitor): output terminals which allow an external
loudspeaker to be connected as a monitor. It has a 1 W internal amplifier. It only monitors the AUX IN
input, controlled with the AUX volume, and adjustable level with LEVEL/MOH control on the rear panel.
16.- TEL. INPUT: telephone input terminals. Allow connection to a telephone switchboard to make
announcements from the switchboard with priority over the rest of the inputs. Consult the characteristics
of the switchboard in order to adjust the input level of the amplifier. The signal level can be adjusted with
the TEL. LEVEL control on the rear panel.
Note: the amplifier is supplied with priority deactivated. In order to activate this function you must turn
the MUTE/SENS control clockwise to its maximum (maximum priority).
17.- TEL. LEVEL: TEL. INPUT volume control. This allows the volume of the telephone switchboard which
is connected to the TEL. INPUT terminals to be adjusted. Turning the control clockwise increases the
volume and anti-clockwise decreases it.