WARNINGS:
• TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER
AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE
POWER IS OFF BEFORE WIRING!
• To be installed and/or used in accordance with appropriate
electrical codes and regulations.
• If you are not sure about any part of these instructions, consult
an electrician.
TO INSTALL
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER
AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF
BEFORE WIRING!
2. Wire device only with 3 conductor cords of the following type: UL Types –
SJTW, SJOW, SJTOW, SJTOOW, SJEOW, STW, STOW and STOOW.
ASSEMBLY PROCEDURE:
(a) Depending upon cable outer jacket diameter, choose a grommet and
clamp size from the Table - Grommet and Clamp Size. The table
indicates correct grommet and clamp size to be used for specific cable
sizes/types.
(b) Slip grommet over cord outer jacket at least 1.5 inches.
(c) Remove outer jacket of cord 7/8 in. (2.2 cm) from end.
(d) Strip each conductor 23/64 in. (0.91 cm) and twist strands tightly together.
DO NOT TIN ENDS.
(e) Insert wire-stripped ends under the appropriate terminal clamps: BLACK
wire under the BRASS screw, WHITE wire under the SILVER screw, and
GREEN wire under the GREEN screw. Torque each wire terminal screw
between 10 to 14 in-lbs. DO NOT OVER-TIGHTEN.
(f) Move grommet along cord to proper location and into sealing well.
(g) Attach cord clamp (observe clamp orientation as shown in Diagram).
Outer cord jacket must extend fully under cord clamp. Fully seat
each cord clamp screw and alternately tighten between 15 to 20 in-lbs. of
torque. DO NOT OVER-TIGHTEN.
(h) Place back cover in position. Torque each back cover screw between 12 to
18 in-lbs. DO NOT OVER-TIGHTEN.
TEST INSTRUCTIONS FOR GFCI
1. Plug device into receptacle.
a. Auto-Reset Devices: GREEN power indicator (LOAD) goes ON. If the
fault status indicator light turns ON or continuously blinks RED, or if the
GFCI cannot reset, go to the Self-Test Operation section.
b. Manual-Reset Devices: Press TEST/RESET button and release.
GREEN power indicator (LOAD) goes ON. If fault status indicator light
turns ON or continuously blinks RED, or if GFCI cannot reset, refer to the
Self-Test Operation section.
2. Press TEST/RESET button and release. Power indicator (LOAD)
must go OFF.
3. Press TEST/RESET button and release. Power indicator (LOAD)
must go ON for use.
CAUTION: DO NOT USE THIS DEVICE IF ABOVE TEST FAILS. TEST UNIT
BEFORE EACH USE. DO NOT TEST THIS UNIT WITH THE CONNECTED
LOAD IN THE "ON" POSITION.
SELF-TEST OPERATION
A Self-Test GFCI has all the features of a conventional GFCI right-angle plug.
In addition, this right-angle plug tests itself periodically to confirm that the GFCI
electronics are functional. The LOAD indicator light will be solid GREEN when
the GFCI is powered from the LINE side and working correctly.
Self-Test Indications: If fault indicator light is solid or continuously flashing
Red, a problem may exist. Press the TEST/RESET button to trip the GFCI. If
unable to reset, replace the GFCI.
NOTE: Fault status indicator may flash RED at power "ON" and reset.
Patents covering this product, if any, can be found on Leviton.com/patents.
SmartlockPro
®
is a trademark of Leviton Manufacturing Co., Inc., registered in the
United States, Canada, Mexico, and China.
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
IC STATEMENT (*will make space for this below FCC statement)
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this
device must accept any interference, including interference that may cause undesired operation of the device.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada ULC to the attention of the Quality Assurance
Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1-800-405-5320.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship
under normal and proper use for two years from the purchase date. Leviton's only obligation is to correct such defects by repair or replacement, at its option. For details visit www.
leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product
is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in
accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied
warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years. Leviton
is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or
delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com(Canada Only) www.leviton.com.
SmartlockPro
®
Portable Self-Test Ground
Fault Circuit Interrupter Right-Angle Device
Cat. Nos. GSRA1 and GSRM1, Rated: 15A-120VAC, 60Hz, 1800W HP: 3/4
Cat. Nos. GSRA2 and GSRM2, Rated: 20A-120VAC, 60Hz, 2400W HP: 3/4
CAUTIONS:
• For Auto-Reset units GSRA1 and GSRA2 ONLY: The connected load should be turned OFF
during a power failure as this device will automatically reset when power is restored. This device
will NOT automatically reset after a ground fault is detected while in use.
• For Auto-Reset units GSRA1 and GSRA2 ONLY: Power will automatically be applied to the
load wires when the device is energized.
• This device protects against current leakage caused by ground faults only. It does not protect
against overcurrent or short circuits.
• This device is suitable for temporary outdoor use, however DO NOT immerse this product in water.
• Plug this device directly into an outlet. DO NOT plug it into an extension cord.
• Use this device with copper wire only.
• Your device may differ from the illustrations depicted.
• May be pre-wired to cable of any specified length (max. 50 ft).
INSTALLATION INSTRUCTIONS
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
*NOTE: Cord jacket must extend fully under cord clamp.
*REMARQUE : tout le pourtour de la gaine doit être sous le collier de cordon.
*NOTA: El forro del cordón debe estar totalmente extendido debajo de la abrazadera.
FAULT
LOAD
Table - Grommet and Clamp Size
No. of
Diameter
Wire Gauge
Conductors
(nominal)
16
3
0.330 in.
14
3
0.370 in.
12
3
0.435 in.
WIRE TYPE ST
18
3
0.365 in.
16
3
0.391in.
14
3
0.550 in.
12
3
0.597 in.
ALLOWABLE CABLE OUTER JACKET DIAMETER FOR
GROMMET / CORD CLAMP:
SMALL: 0.330 in. - 0.435 in.
PK-A3380-10-02-2B
Diagram / Schéma / Diagrama
Cord Clamp
Collier de cordon
Abrazadera del cordón
Back Cover
Coquille
Cubierta posterior
Maximum
Grommet
Current
WIRE TYPE SJ
SMALL - I.D.
13-Amps
0.210 in.
SMALL - I.D.
15-Amps
0.210 in.
SMALL - I.D.
20-Amps
0.210 in.
SMALL - I.D.
10-Amps
0.210 in.
SMALL - I.D.
13-Amps
0.210 in.
MEDIUM-
15-Amps
I.D. 0.310 in.
LARGE -
20-Amps
I.D. 0.475 in.
MEDIUM: 0.550 in.
LARGE: 0.597 in.
ENGLISH
Ring Seal
Bague d'etanchéité
Anillo de sellado
Cord Jacket
Gaine
Forro del cordón
Cord Clamp
SMALL
SMALL
SMALL
SMALL
SMALL
LARGE
LARGE

Publicidad

loading

Resumen de contenidos para Leviton SmartlockPro GSRA1

  • Página 1 LIMITED 2 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date.
  • Página 2 à une durée de 2 ans. Leviton décline toute responsabilité envers les dommages indirects, particuliers ou consécutifs, incluant, sans restriction, la perte d’usage d’équipement,...

Este manual también es adecuado para:

Smartlockpro gsrm1Smartlockpro gsra2Smartlockpro gsrm2