Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

PROBLEM
Pilot light does not light up
Pilot light does not stay on
Burner does not light

PROBLEM CHECKLIST

PROBABLE CAUSES
Gas valve may be OFF
Fuel tank empty Opening
blocked
Air in supply system Loose
connections
Debris around pilot Loose
connections
Defective thermocouple
Gas leak in line
Lack of fuel pressure
Pressure is low
Opening blocked Control not ON
Thermocouple defective
Pilot light assembly is bent Not
in correct location
15
SOLUTIONS
Turn on gas valve Refill LPG tank
Clean or replace opening Bleed air
from lines Check all fittings
Clean soiled area
Tighten connections Replace
thermocouple
Check connections Tank almost
empty. Refill LPG tank.
Tank almost empty.
Refill the LPG tank. Remove and
clean. Turn on valve
Replace thermocouple
Position pilot correctly Position
correctly and try again.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Estgas14000seta