All manuals and user guides at all-guides.com
ENGLISH
RANGE
MIN/MAX
HOLD
DTEK
Low Z
Duty
m
m
COM
Frequency (Hz) / Duty Cycle < 1MHz
5.
Features:
HOLD
PRESS
SELECT
DTEK
Low Z
º
F
º
º
C
Duty
Hz
6.
Temperature
Features:
HOLD
MAX/MIN
PRESS
DTEK
Low Z
º
F
º
C
Duty
°F
•
Do not apply voltage to thermocouple.
• Fahrenheit range: -58° to 1832°F
• Celsius range: -50° to 1000°C
Testing Fuses
PRESS
SELECT
F
C
Duty
º
º
º
• "O.L." indicates blown fuse.
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range
Resolution
400mV ~ 400V
0.1mV ˜ 0.1V
˜ 0.1V
˜
1000V
1V
Overload Protection:
1000V
> 10MΩ, < 100pF
I
nput Impedance (Nominal):
Input Impedance (Low-Z):
> 3kΩ, < 200pF, up to 600V RMS
AC Voltage Measurement
Range
Resolution
400mV
0.1mV
4V ~ 400V
1mV ~ 0.1V
1000V
1V
Overload Protection:
1000V RMS
> 10MΩ, < 100pF
Input Impedance (Nominal):
Input Impedance (Low-Z):
> 3kΩ, < 200pF, up to 600V RMS
Frequency Response:
40Hz ~ 20kHz
Response:
True RMS
*Accuracy for 400Hz ~ 1kHz range only
Continuity Features:
HOLD
MAX/MIN
• Display shows resistance.
• Buzzer sounds if less than 30 Ω
DTEK
m
m
COM
Duty
REL
F
C
Duty
º
º
m
m
COM
°C
REL
RANGE
MIN/MAX
HOLD
º
F
º
C
m
m
COM
Accuracy
± (0.5% + 4 digits)
±( 0.8% + 10 digits)
Accuracy
40Hz ~ 400Hz
400Hz ~ 20kHz
± (2.5% + 10 digits)
± (0.75% + 5 digits)
± (2.0% + 8 digits)
± (0.75% + 8 digits) ± (2.0% + 8 digits)*