6. Installation and Assembly

This equipment may only be installed by a qualified technician who is familiar with the installation, monitoring and
maintenance of this type of equipment, and uses suitable tools.
Mechanical
To ensure safe operation, the equipment must be firmly fixed.
The installation must prevent contact with the fan's impeller, through the use of grilles, accessories, or by installing
a connecting tube of a suitable length.
The equipment must be installed in such a way that the whole of its surface area is adhered to the surface on
which it is installed.
The installation must be such that the weight of the duct system is not supported by the equipment.
Once the mechanical assembly is complete, it is important to check that the impeller turns freely, with no friction or
tension
If there is a possibility of water condensing in the equipment, external preventive measures must be taken.
Electrical
Check if the equipment is connected to the power source in accordance with the instructions on the cover of the
connection box.
For the electrical supply connection for this fan, special cable certified as compliant with fire regulations must be
used, of a suitable cross-section for the current the fan uses. (RFV, RFH)
Select a power cable with a suitable cross-section for the current used by the equipment. (RFHD)
IMPORTANT: When the equipment is controlled by reducing the voltage, the motor current may be higher than
the rated value.
Check if the electrical characteristics stated on the plate correspond to the power supply.
An external protective component must be connected (a relay, magneto-thermal protection system or fuse), in
accordance with current regulations.
The equipment's earth connection must be connected.
If the motor speed control is used, it must be guaranteed that the motor will operate correctly.
It is necessary to ensure a minimum rotation speed that will allow the extraction non-return valves to be activated
(if they have been installed).
Start-up
Before starting up the machine, check that all the joints and closures are correctly assembled, to prevent external
particles or fluids entering the equipment.
After starting up the motor, it is important to check that the motor is turning correctly, without vibrations or unusual
noises.
A check must be made to ensure that the motor's actual power consumption does not exceed the level stated on
the equipment's label and that it does not heat up excessively.
The machine must not be switched on and off intermittently, as this could damage the winding of the motor or the
insulation, due to overheating.
7. Maintenance
Maintenance must be performed by qualified technicians.
The bearings are greased and sealed for life. Nevertheless, changing them about every 20.000 hours effective
running time is recommended.
If the fan is not equipped with an air filter, the only maintenance required is to clean the impeller; this must be
done at least once every six months.
Care must be taken when cleaning the impeller, in order not to affect its balance.
It is not advisable to use chemical cleaners or aggressive substances, as they could damage the equipment.
If a part must be replaced, consult the distributor.
8. Disposal
Careless or negligent disposal of the equipment may cause contamination. The disposal process must be carried out in
compliance with the standards and regulations applicable in the country.
9. Warranty
Incorrect use of the equipment and failure to follow up the instructions in this manual may result in the cancellation of the
warranty.