4.2 Installation
description
4.3 Function test
WARNING
Risk of fatality due to failures or faults in electromagnetically
sensitive devices!
The electromagnetic radiation of the product can cause faults in sensi-
tive parts (e.g. in medical equipment). The functionality thereof will be
adversely affected.
> Do not place product close to electromagnetically sensitive
devices.
> Pay attention to the safety instructions for the
electromagnetically sensitive devices.
> If you have any doubts regarding compatibility, please contact
the manufacturer.
NOTE
Damage to product due to incorrect installation!
> Adhere to installation requirements.
> Do not trap or damage wires during installation.
> Never start up and use the product if any wires have been
damaged.
> Always drill holes in the door leaf from both sides to prevent
pieces of the door from breaking away.
The installation is described using only pictures.
For step-by-step installation instructions, see picture sec-
tion starting at page 19.
After completing installation, perform a manual function test.
Push the lever handle at the inside of the door:
Correct result:
• Latchbolt is pulled back (escape function).
• Door can always be opened.
Push the lever handle at the outside of the door:
Correct result:
• The coupling is in the uncoupled position. The lever handle moves without pulling
back the latchbolt. The door cannot be opened.
• When the lever handle is released, it must be automatically returned to the
horizontal idle position by the return spring.
• The door cannot be opened.
If this is not the case, check the individual installation steps.