- When the "n93" flashes, the citric acid pack is empty. After the fully automated chemical cleaning is completed, refill the citric
acid pack according to "2. CHEMICAL REPLACEMENT".
- When the display shows "n70", water is not coming into the unit. Check for low water.

6. PREPARING THE KIT FOR LONG STORAGE

When the fully automated chemical cleaning function is not used for 2 months or more, fill the citric acid pack half with water
and carry out the manual chemical cleaning process once (See "1. TRIAL RUN"). This is to wash out the citric acid solution
remaining in the tube. Otherwise, the citric acid solution in the tube may dry and cause check valve failure.