Fuel Filter Strainer; Muffler - EcoFlow Smart Generator Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 107

3.5 Fuel Filter Strainer

1. Take off the fuel cap
and fuel filter screen.
Never use fuel in any place near smoke or flames.
Warning
Caution
Be sure to tighten the fuel cap.

3.6 Muffler

1. Unscrew the bolts.
2. Take off the muffler cap, muffler block and spark plug
arrestor.
3. Clean the carbon deposits on the muffler block and the
spark plug arrestor gently with a steel wire brush to avoid
any damage or scratches to the muffler block and spark
plug collector.
4. Check whether the muffler block or the spark plug arrestor
is damaged, and replace it if damaged.
5. Reinstall the parts in turn.
Warning
Once the generator starts running, the engine and the muffler will become scalding hot. Do not let
your skin or clothes directly touch the engine or muffler during your checks and maintenance.
2. Clean the fuel filter
screen with fuel.
3. Wipe the filter screen and
place it back into the fuel.
4. Reinstall the fuel
cap.
Clean any carbon deposits
17