Please contact your dealer for specific warranty conditions.
Only original spare parts must be used
To request spare parts, please contact your dealer/distributor.
25. TROUBLESHOOTING COMMON PROBLEMS
The cabinet stops or
does not turn on
The cabinet does not
cool sufficiently
Presence of
condensate
Water loss
26. SEASONAL USE AND STORAGE
If the device is not used continuously and is subject to prolonged downtime, it is necessary before its storage, to carry
out a thorough cleaning as described in the appropriate chapter, cover it with a cloth, secure the power cord to the
appliance to prevent it from getting entangled and damaged.
It is important that the storage place is not hot and humid.
THE PRODUCT MAY NOT BE STORED OUTSIDE EXPOSED TO WEATHERING AND DIRECT SUNLIGHT
as described in Chapters 12 and 21.
Cause
The electrical plug is disconnected
•
The compressor goes into
•
protection mode
•
The cabinet is performing a defrost
•
Air intake or air supply are
obstructed
The goods are not neatly loaded
•
The CABINET is close to drafts,
•
heat sources or is warmed by the
sun's rays
The evaporator is frozen
•
Humidity too high
•
The condensate water disposal tank
•
is full due to too much moisture
Solution
Connect the electrical plug
•
Check that the condenser is
•
clean and that the air intake grill
of the motor compartment is
free, otherwise contact support
•
Wait for the end of defrosting
•
Free the vents
Distribute the load evenly on
•
the shelves
Place the CABINET elsewhere
•
or eliminate external causes of
disturbance
Perform defrost
•
Check the environmental
•
conditions and that the device is
not leaning against other
elements (walls, windows,
columns, etc.)
Environmental conditions are
•
not suitable for the correct
operation of the appliance
14