5.3 Exhaust Air Mode

WARNING
Death Risk!
Exhaust gases that are reabsorbed might lead to
poisoning. Exhaust air must not be transferred to
an active smoke or waste gas flue; or a flue used
for ventilation of the places, where heat sources
are installed. If you want to transfer exhaust air
to an inactive smoke or waste gas flue, you need
to obtain permission from an authorized chim-
ney sweep.
If exhaust air is discharged over the external
wall,
a telescopic wall case must be used.

5.4 Air Discharge Line

Information: Manufacturer of appliance can-
not be held responsible for defects caused by
laid pipes.
■ Appliance shows the highest performance
when a short and flat air outlet pipe and a pipe
diameter as large as possible is used.
■ Optimum ventilation performance cannot be
reached and noise of fan increases when long
and rough air outlet pipes and multiple pipe el-
bows or pipe diameters smaller than 150mm are
used.
■ Pipes or hoses used in laying the air outlet
line must be made of inflammable materials.
Circular Pipes
It is recommended that inner diameter should be
150 mm or at least 120 mm.
Flat Channels
Inner Section must be appropriate to the diame-
ter of circular pipes.
Ø150 mm approx. 177 cm²
Ø120 mm approx. 173 cm²
■ Flat channels shouldn't have sharp elbows.
■ Use sealing strips for different pipe diameters.

5.5 Checking the Wall

Wall must be flat, straight and have the sufficient
bearing capacity.
Depth of drilling holes must comply with the
length of bolts. Dowels must fit in properly.
Bolts and dowels in the enclosure are appro-
priate for use in rigid monolithic walls. Use ap-
propriate fasting materials for different construc-
tions (for ex. plasterboard, aerated concrete,
proton bricks).
Maximum weight of your cooker hood is 40 Kg.

5.6 Electrical Connection

WARNING
Electric Shock Danger!
Components in the appliance might have sharp
edges. Connection cable can be damaged. Do
not bend or jam the connection cable during in-
stallation.
Necessary connection data is provided on the
type label found inside your appliance; metal
grease filters must be removed to see the label.
Length of connection line: approx.
1.3 m
This appliance complies with EU interference
elimination guidelines.
DANGER

5.7 Danger of Electric Shock!

It must always be possible to disconnect the
appliance from the electric network. Appliance
must be plugged in a protected contact outlet
that is mounted in accordance with the rules. If
the plug cannot be reached after installation or
during the required fixed connection, there must
be many pole separation assemblies available
with at least 3 mm contact distance to the instal-
lation. Fixed connection must be performed by
an electronics expert only.